A Compact Tunable Diode Laser Absorption Spectrometer to Monitor CO2 at 2.7 μm Wavelength in Hypersonic Flows

نویسندگان

  • Raphäel Vallon
  • Jacques Soutadé
  • Jean-Luc Vérant
  • Jason Meyers
  • Sébastien Paris
  • Ajmal Mohamed
چکیده

Since the beginning of the Mars planet exploration, the characterization of carbon dioxide hypersonic flows to simulate a spaceship's Mars atmosphere entry conditions has been an important issue. We have developed a Tunable Diode Laser Absorption Spectrometer with a new room-temperature operating antimony-based distributed feedback laser (DFB) diode laser to characterize the velocity, the temperature and the density of such flows. This instrument has been tested during two measurement campaigns in a free piston tunnel cold hypersonic facility and in a high enthalpy arc jet wind tunnel. These tests also demonstrate the feasibility of mid-infrared fiber optics coupling of the spectrometer to a wind tunnel for integrated or local flow characterization with an optical probe placed in the flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compact laser difference-frequency spectrometer for multicomponent trace gas detection

Design, performance characteristics, and application of a room temperature mid-infrared laser spectrometer are reported. This compact instrument is based on differencefrequency mixing of a widely tunable external-cavity diode laser and a diode-pumped monolithic Nd:YAG ring laser in periodically poled lithium niobate (PPLN). The differencefrequency tuning range of 3.98 μm to 4.62 μm was sufficie...

متن کامل

Infrared absorption spectrometer for the determination of temperature and species profiles in an entrained flow gasifier.

An absorption spectrometer utilizing a tunable distributed feedback diode laser at 2.3 μm and an interband cascade laser at 3.1 μm has been developed to measure temperature and concentrations of CO, CH4, C2H2, and H2O under gasification conditions. A wavelength division multiplexing approach using a single ZrF4-fiber was used to measure bot...

متن کامل

Rapid, Time-Division Multiplexed, Direct Absorption- and Wavelength Modulation-Spectroscopy

We present a tunable diode laser spectrometer with a novel, rapid time multiplexed direct absorption- and wavelength modulation-spectroscopy operation mode. The new technique allows enhancing the precision and dynamic range of a tunable diode laser absorption spectrometer without sacrificing accuracy. The spectroscopic technique combines the benefits of absolute concentration measurements using...

متن کامل

Applied Optics Photoacoustic Measurements of the Co2 Absorption Coefficients within Infrared Region of Co2 Laser Spectrum

Absorption coefficients of the carbon dioxide (CO2) were measured at atmospheric pressure and room temperature by photoacoustic technique with a cw, line-tunable, frequency stabilized CO2 laser. The CO2 laser spectrum of our system consists in 53 lines with wavelengths ranging from 9.2 μm to 10.8 μm and power levels below 5 W. Measured values of the CO2 absorption coefficients are typically of ...

متن کامل

b404552c doc..b404552c chapter .. Page772

The performance of a home-built tunable diode laser (TDL) spectrometer, aimed at multi-line detection of carbon dioxide, has been evaluated and optimized. In the regime of the (301)III / (000) band of CO2 around 1.6 mm, the dominating isotope species CO2, CO2, and 12C18O16O were detected simultaneously without interference by water vapor. Detection limits in the range of few ppmv were obtained ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2010