Saline instillation before tracheal suctioning decreases the incidence of ventilator-associated pneumonia.

نویسندگان

  • Pedro Caruso
  • Silvia Denari
  • Soraia A L Ruiz
  • Sergio E Demarzo
  • Daniel Deheinzelin
چکیده

OBJECTIVES To compare the incidence of ventilator-associated pneumonia (VAP) with or without isotonic saline instillation before tracheal suctioning. As a secondary objective, we compared the incidence of endotracheal tube occlusion and atelectasis. DESIGN Randomized clinical trial. SETTING AND PATIENTS The study was conducted in a medical surgical intensive care unit of an oncologic hospital. We selected consecutive patients needing mechanical ventilation for >72 hrs. Patients were allocated into two groups: a saline group that received instillation of 8 mL of saline before tracheal suctioning and a control group which did not. VAP was diagnosed based on clinical suspicion and confirmed by bronchoalveolar lavage quantitative culture. The incidence of atelectasis on daily chest radiography and endotracheal tube occlusions were recorded. The sample size was calculated to a power of 80% and a type I error probability of 5%. MEASUREMENTS AND MAIN RESULTS One hundred thirty patients were assigned to the saline group and 132 to the control group. The baseline demographic variables were similar between groups. The rate of clinically suspected VAP was similar in both groups. The incidence of microbiological proven VAP was significantly lower in the saline group (23.5% x 10.8%; p = 0.008) (incidence density/1.000 days of ventilation 21.22 x 9.62; p < 0.01). Using the Kaplan-Meier curve analysis, the proportion of patients remaining without VAP was higher in the saline group (p = 0.02, log-rank test). The relative risk reduction of VAP in the saline instillation group was 54% (95% confidence interval, 18%-74%) and the number needed to treat was eight (95% confidence interval, 5-27). The incidence of atelectases and endotracheal tube occlusion were similar between groups. CONCLUSIONS Instillation of isotonic saline before tracheal suctioning decreases the incidence of microbiological proven VAP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the Effect of Using Normal Saline and Distilled Water for Tracheal Suctioning on the Incidence of Ventilator-associated Pneumonia and Hemodynamic Indexes in Ventilator-dependent Patients

Background and Aims: VAP prevention is a top priority in the intensive care units. The study was conducted to compare the effect of using normal saline and distilled water for tracheal suctioning on the incidence of ventilator-associated pneumonia and hemodynamic indexes in ventilator-dependent patients. Methods: The present study is a randomized clinical trial that was conducted from 2017 to 2...

متن کامل

Instillation of normal saline before suctioning reduces the incidence of pneumonia in intubated and ventilated adults.

QUESTION Does the instillation of normal saline before suctioning reduce the incidence of ventilator-associated pneumonia in intubated and ventilated adults? DESIGN Randomised, controlled trial with blinded outcome assessment. SETTING The medical/surgical intensive care unit of a tertiary oncology hospital in Brazil. PARTICIPANTS Adults expected to require at least 72 hours of mechanical ...

متن کامل

استفاده‌ از نرمال‌ سالین‌ در ساکشن‌ لوله‌ تراشه‌ بر گازهای‌ خون‌ شریانی‌

  Background : Disorder in diffusion of blood gases almost always is clue to collection of secretion in respiratory airways. So protecting the airway, correct suctioning to remove the secretion and maintenance of air way potency are necessary interventions in patient with end tracheal tube .   Objective : To determine and compaire arterial blood gas in patient with open heart surgery with and w...

متن کامل

Ventilator-Associated Pneumonia in Patients Admitted to Intensive Care Units, Using Open or Closed Endotracheal Suctioning

BACKGROUND Critically ill patients under mechanical ventilation require frequent suctioning of airway secretion. Closed suction permits suctioning without disconnection from ventilator; so it might decrease hypoxemia and infection rate. OBJECTIVES This study aimed to evaluate the effect of closed tracheal suction system (CTSS) versus open tracheal suction system (OTSS). PATIENTS AND METHODS...

متن کامل

Tracheal secretion management in the mechanically ventilated patient: comparison of standard assessment and an acoustic secretion detector.

BACKGROUND Standard indications for endotracheal suctioning are often based on clinical judgment on the deterioration of the patient's condition, and/or routine suctioning. TBA Care is a secretion detector that analyses airway sounds and indicates the need for suctioning. OBJECTIVE To determine the efficacy of TBA Care in detecting retained secretions, compared to standard indications. METH...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical care medicine

دوره 37 1  شماره 

صفحات  -

تاریخ انتشار 2009