Permittivity determination via phantom and in vivo B1 mapping

نویسندگان

  • U. Katscher
  • P. Karkowski
  • T. Voigt
چکیده

Introduction Tissue permittivity might serve as diagnostic parameter, e.g., for oncology [1]. However, the diagnostic use of the permittivity is significantly hampered by the lack of suitable methods to determine the permittivity in vivo. A possible approach for the determination of permittivity in vivo is given by analyzing the B1 map in the framework of standard MRI, called "Electric Properties Tomography" (EPT) [2]. Hitherto, studies were focussed on the ability of EPT to reconstruct the electric conductivity and local SAR [2]. This study focuses on the EPT reconstruction of the permittivity via numerous phantom and in vivo experiments. Theory Permittivity (together with the electric conductivity) can be estimated from the active magnetic RF field component H via a re-arrangement of the Maxwell equations (see equation) [2]. Here, εr denotes the relative permittivity, ε0 the vacuum permittivity, σ the electric conductivity, and ω the Larmor frequency. The amplitude of H can be determined via standard B1 mapping techniques. The phase of H can be determined, e.g., via the phase of a spin echo image. However, since the permittivity influences predominantly the amplitude of H, also reconstructions assuming a constant phase of H were tested. The reconstruction equation is a refinement of the reconstruction discussed in [2], i.e., the reconstruction was performed twice, for a coronal and sagittal reconstruction plane, and the two results were superimposed. The resulting equation does not require any assumption concerning the unknown magnetic field components H and Hz. Additionally, compared with the reconstruction suggested in [3,4], it does not require a numerically demanding second derivative of H. As in [2-4], the proposed reconstruction yields absolute values of the permittivity. Methods Distilled water was mixed with 2-propanol in 8 different concentrations to obtain εr between 35 and 80 (from 25% to 100% water). Additionally, different physiologic conductivities σ = 0.0/0.5/0.8/2.0 S/m were achieved by adding respective amounts of NaCl. However, due to the limited salt solubility in propanol, not all combinations of σ and εr could be realized. Bottles with a volume of 200 ml were filled with the fluids, and 2.5 ml Magnevist (Bayer Schering Pharma AG, Berlin, Germany) per liter of phantom fluid was added to enhance the MR signal. Finally, the resulting εr were checked by a dedicated sensor [5] and the resulting σ by a commercial conductivity-meter (HI8733, Hanna Instruments, USA). Experiments were performed on a Philips Achieva 1.5T system (Philips Health Care, Best, The Netherlands) using a transmit/receive quadrature head coil. To determine the amplitude of H, "Multiple TR B1 Mapping" (MTM) [6] was used, based on 3 repetitions of the "Actual Flip angle Imaging" (AFI) sequence [7] with different TR pairs (TR11/TR21=30/185 ms, TR12/TR22=30/200 ms, TR13/TR23=30/320 ms). Further sequence parameters were α = 60°, voxel size = 1.5×1.5×4 mm3, TE = 1.3 ms. The phase of H was estimated as suggested in [2] via a separate turbo-spin-echo sequence (TE/TR = 25/750 ms, α = 90°, turbo factor = 8, same geometry as for the B1 mapping). Reconstruction was performed using the equation given above. Finally, the described sequences were applied to the head of a volunteer, and the permittivity was reconstructed with and without phase information. Results Reconstructed and expected phantom permittivities agree well for all investigated conductivities (Fig. 1a). Results of the volunteer study are shown in Fig. 2. The average εr in white/gray matter and Cerebro-Spinal Fluid (CSF) agree with literature values (Tab. 1). Discussion / Conclusion This study underlines the ability of EPT to determine the permittivity in phantoms and in vivo, which might become a new parameter for clinical diagnosis. To the best of the authors' knowledge, it is the first time that permittivity has been measured with standard MR. The achievable spatial resolution is of the order of the acquired B1 maps, reduced by blurring arising from the applied calculus operations. Total EPT scan time can be reduced by skipping the phase determination due to its negligible impact on the reconstructed permittivity, at least for the electric properties of human tissue. The occurring noise seems to be higher than for the reconstructed conductivity [2]. This feature, which might arise from ε0εr << σ/ω for human tissue at Larmor frequency, shall be investigated in a future study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Turbo Spin Echo Bloch Siegert Shift B1 Mapping

An interesting method for B1 mapping based on the Bloch-Siegert (BLS) shift was recently presented (1,2) for gradient echo (FLASH) and Spin Echo (SE) sequences. This method uses off-resonant pulses before signal acquisition to encode the B1 information into the signal phase. Fast B1 mapping is possible since the repetition time has only minor influence on the quality of the phase information. I...

متن کامل

SA2RAGE: a new sequence for fast B1+ -mapping.

At high magnetic field strengths (≥ 3T), the radiofrequency wavelength used in MRI is of the same order of magnitude of (or smaller than) the typical sample size, making transmit magnetic field (B1+) inhomogeneities more prominent. Methods such as radiofrequency-shimming and transmit SENSE have been proposed to mitigate these undesirable effects. A prerequisite for such approaches is an accurat...

متن کامل

Motion-robust cardiac B1+ mapping at 3T using interleaved bloch-siegert shifts.

PURPOSE To develop and evaluate a robust motion-insensitive Bloch-Siegert shift based B1+ mapping method in the heart. METHODS Cardiac Bloch-Siegert B1+ mapping was performed with interleaved positive and negative off-resonance shifts and diastolic spoiled gradient echo imaging in 12 heartbeats. Numerical simulations were performed to study the impact of respiratory motion. The method was com...

متن کامل

Regularized Estimation of Magnitude and Phase of Multi-Coil $B_1$ Field Via Bloch-Siegert $B_1$ Mapping and Coil Combination Optimizations

Parallel excitation requires fast and accurate B1 map estimation. Bloch-Siegert (BS) B1 mapping is very fast and accurate over a large dynamic range. When applied to multi-coil systems, however, this phase-based method may produce low signal-to-noise ratio estimates in low magnitude regions due to localized excitation patterns of parallel excitation systems. Also, the imaging time increases wit...

متن کامل

Single acquisition electrical property mapping based on relative coil sensitivities: A proof-of-concept demonstration.

PURPOSE All methods presented to date to map both conductivity and permittivity rely on multiple acquisitions to compute quantitatively the magnitude of radiofrequency transmit fields, B1+. In this work, we propose a method to compute both conductivity and permittivity based solely on relative receive coil sensitivities ( B1-) that can be obtained in one single measurement without the need to n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009