Three-dimensional flow structures past a bio-prosthetic valve in an in-vitro model of the aortic root
نویسندگان
چکیده
The flow field past a prosthetic aortic valve comprises many details that indicate whether the prosthesis is functioning well or not. It is, however, not yet fully understood how an optimal flow scenario would look, i.e. which subtleties of the fluid dynamics in place are essential regarding the durability and compatibility of a prosthetic valve. In this study, we measured and analyzed the 3D flow field in the vicinity of a bio-prosthetic heart valve in function of the aortic root size. The measurements were conducted within aortic root phantoms of different size, mounted in a custom-built hydraulic setup, which mimicked physiological flow conditions in the aorta. Tomographic particle image velocimetry was used to measure the 3D instantaneous velocity field at various instances. Several 3D fields (e.g. instantaneous and mean velocity, 3D shear rate) were analyzed and compared focusing on the impact of the aortic root size, but also in order to gain general insight in the 3D flow structure past the bio-prosthetic valve. We found that the diameter of the aortic jet relative to the diameter of the ascending aorta is the most important parameter in determining the characteristics of the flow. A large aortic cross-section, relative to the cross-section of the aortic jet, was associated with higher levels of turbulence intensity and higher retrograde flow in the ascending aorta.
منابع مشابه
Physiological vortices in the sinuses of Valsalva: An in vitro approach for bio-prosthetic valves
PURPOSE The physiological flow dynamics within the Valsalva sinuses, in terms of global and local parameters, are still not fully understood. This study attempts to identify the physiological conditions as closely as possible, and to give an explanation of the different and sometime contradictory results in literature. METHODS An in vitro approach was implemented for testing porcine bio-prost...
متن کاملSuccessful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis
Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...
متن کاملEvaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping.
We studied the value of two-dimensional Doppler echocardiographic color flow mapping for identifying normal transvalve flow profiles and valve malfunction in 20 patients with Björk-Shiley prosthetic valves. Seven patients had Björk-Shiley prosthetic valves in the aortic position alone, seven in the mitral position, and six had prosthetic valves in both the aortic and mitral positions. In 10 pat...
متن کاملThe Effect of Valve Lift on In-Cylinder Flow, Performance and Emissions in a Turbocharged DI Diesel Engine
A computational optimization was performed for a direct-injection diesel engine using three-dimensional modeling. Fully transient CFD analyses of different valve profile strategies for the intake and compression strokes were performed to evaluate the effects on both engine performance and in-cylinder flow-field evolution. The turbulence model was used along with the second order linear upwin...
متن کاملParticle Trace Visualization of Flow Patterns Downstream of a Prosthetic Aortic Valve in Patients
Introduction Late complications such as hemolysis and thrombus formation in patients with an implanted prosthetic heart valve have been related to fluid dynamic characteristics [ 11. Specific blood flow patterns such as flow reversal and vortex flow have been considered to contribute to thrombus formation [2]. In order to detect alterations of flow fields around prostheses in humans MR velocity...
متن کامل