Reliability of isokinetic evaluation in passive mode for knee flexors and extensors in healthy children.
نویسندگان
چکیده
BACKGROUND The isokinetic dynamometer has been considered the gold-standard measurement of muscle performance. However, the reliability for the passive mode in children has not been reported to date. OBJECTIVES The purpose was to evaluate the reliability of the isokinetic dynamometer in passive mode in children. METHOD Twenty-one healthy children (ten girls, eleven boys), aged 5 to 12 years (age: 8.5±2.2 years), were evaluated using an isokinetic dynamometer. Each participant was tested twice with a one-week interval and performed five consecutive cycles of knee extension and flexion. The test was performed at 60º/s in the concentric passive mode and the children performed maximal contractions. The measured variables were peak torque, average peak torque, total work, and average power, time to peak torque and angle of peak torque for dominant and non-dominant lower limbs. Reliabilities were determined using intraclass correlation coefficient (ICC3,1), standard error of measurement (SEM and SEM%), and coefficient of variation (CV). RESULTS We found good reliability in both lower limbs for peak torque, average peak torque, total work and average power of knee flexors and extensors, with ICC3,1 values greater than 0.80; SEM ranging from 6.7 to 79.2; SEM% ranging from 10.4% to 16.8%; CV lower than 15%. Bland-Altman analysis showed that the bias was low than 10% and limits of agreement (LOAs) ranging from 33.9% to 59.2%, and -28.8% and -52.8%, showing that measures tended to disagree. However, time to peak torque (ICC3,1<0.68; SEM > 0.34; SEM%>37.4%; CV>41.7%; bias >24.0%; LOA>101.0%) and angle of peak torque (ICC3,1<0.76; SEM>9.3; SEM%>27.6%; CV>15.3%; bias>11.0%; LOA>61.0%) were not reliable. CONCLUSIONS The findings indicate that isokinetic evaluation in passive mode for knee extensors and flexors of dominant and non-dominant lower limbs of children without disabilities was reliable for peak torque, average peak torque, work, and power. However, average time to peak torque and angle of peak torque were not reliable.
منابع مشابه
Isokinetic dynamometry of the knee extensors and flexors in
Background :This paper explores the gender-related bilateral differences of extensor and flexor torques of the knee joint at low and high angular velocities in Iranian healthy males and females. Methods : 70 healthy subjects (29 males (26.61±4.34 yrs and 41 females with average age of 23.07±3.70 yrs)) were participated in this study. Isokinetic peak torque values for knee extensors and flex...
متن کاملTest-retest reliability of isokinetic dynamometry for the assessment of spasticity of the knee flexors and knee extensors in children with cerebral palsy.
OBJECTIVE To assess test-retest reliability of the peak resistance torque and slope of work methods of spasticity measurement of the knee flexors and extensors in children with cerebral palsy (CP). DESIGN Test-retest reliability study. SETTING Pediatric orthopedic hospital. PARTICIPANTS Fifteen children with CP. INTERVENTION Knee extensor and flexor spasticity was assessed with an isoki...
متن کاملIsokinetic dynamometry of the knee extensors and flexors in Iranian healthy males and females
BACKGROUND This paper explores the gender-related bilateral differences of extensor and flexor torques of the knee joint at low and high angular velocities in Iranian healthy males and females. METHODS 70 healthy subjects (29 males (26.61±4.34 yrs and 41 females with average age of 23.07±3.70 yrs)) were participated in this study. Isokinetic peak torque values for knee extensors and flexors i...
متن کاملTest-retest reliability and validity of isometric knee-flexion and -extension measurement using 3 methods of assessing muscle strength.
CONTEXT Physicians and clinicians need portable, efficient, and cost-effective assessment tools to determine the effectiveness of rehabilitation programs after knee injury. Progress in rehabilitation should be evaluated using valid and reliable measurement methods. OBJECTIVE To examine the test-retest reliability of portable fixed dynamometry (PFD), handheld dynamometry (HHD), and isokinetic ...
متن کاملArthroscopically Assisted Combined Anterior and Posterior Cruciate Ligament Reconstruction with Autologous Hamstring Grafts–Isokinetic Assessment with Control Group
OBJECTIVE The aim of the study was to: 1) evaluate the differences in pre-post operative knee functioning, mechanical stability, isokinetic knee muscle strength in simultaneous arthroscopic patients after having undergone an anterior cruciate ligament (ACL) and the posterior cruciate ligament (PCL) with hamstring tendons reconstruction, 2) compare the results of ACL/PCL patients with the contro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian journal of physical therapy
دوره 17 2 شماره
صفحات -
تاریخ انتشار 2013