Creatine kinase isoenzyme MB in myocardial infarction: methods compared.
نویسندگان
چکیده
Several methods are available for specifically identifying and assessing the activity of MB isoenzyme of creatine kinase in serum. We compared two electrophoretic techniques with three column-chromatographic ones for efficacy in the diagnosis of myocardial infarction. No technique was considered absolute, but we found surprisingly large errors of diagnosis in the column-chromatographic techniques, attributable to incomplete elution.
منابع مشابه
Use of creatine kinase MB isoenzyme for diagnosing myocardial infarction when total creatine kinase activity is high.
The usefulness of measuring creatine kinase MB isoenzyme for diagnosing myocardial infarction when activities of total creatine kinase are very high is unclear. We conducted a retrospective study in an urban hospital that serves a largely indigent population. We concentrated on 146 patients whose creatine kinase activity was greater than 1000 U/L (upper limit of normal: 165 U/L for women and 22...
متن کاملRelative increase in creatine kinase MB isoenzyme during reperfusion after myocardial infarction is method dependent.
We compared relative increases in creatine kinase (EC 2.7.3.2) MB isoenzyme (CK-MB) after reperfusion in myocardial infarction for four popular methods: electrophoresis, immunoinhibition, the "Magic Lite" (Ciba-Corning) system, and the Stratus (Dade). In a method comparison study, we confirmed that all four methods correlated (r greater than 0.95). Electrophoresis demonstrated the greatest scat...
متن کاملCreatine kinase MB isoenzyme studies in diagnosis of myocardial infarction.
Serial measurements of the MB isoenzyme of creatine kinase, total creatine kinase, aspartate mainotransferase, and urea stable lactate dehydrogenase have been made in the serum of a series of 139 patients admitted with a diagnosis of suspected myocardial infarction. Serum MB isoenzyme measurements have also been made on postoperative surgical patients and patients with medical disorders known t...
متن کاملThe mass concentrations of serum troponin T and creatine kinase-MB are elevated before creatine kinase and creatine kinase-MB activities in acute myocardial infarction.
The time-related frequency of elevated results for the mass concentrations of the MB isoenzyme of creatine kinase and of troponin T were compared with that of creatine kinase and creatine kinase-MB activity in patients with acute myocardial infarction. Patients (322; 175 with and 147 without myocardial infarction) consecutively admitted for evaluation of possible acute myocardial infarction wer...
متن کاملPerformance characteristics of creatine kinase-MB isoenzyme measured with an immunoenzymometric and an immunoinhibition assay in acute myocardial infarction with and without thrombolytic therapy.
In a time study we compared the analytical and clinical performance of the Tandem Icon QSR CK-MB enzyme-immunoassay (Hybritech) (creatine kinase-MB) and a creatine kinase-MB immunoinhibition method (Boehringer Mannheim GmbH) (creatine kinase-B). Two hundred and ninety-nine serum samples from 38 patients suspected of acute myocardial infarction were collected at regular intervals during 48 hours...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 23 3 شماره
صفحات -
تاریخ انتشار 1977