Reconstruction and frequency mapping with phase-cycled bSSFP

نویسندگان

  • F. Santini
  • K. Scheffler
چکیده

Introduction. Balanced steady-state free precession (bSSFP) imaging is a fast acquisition technique giving high signal with very short repetition times. However, its steady-state is very sensitive to off-resonances (and therefore B0 inhomogeneity), leading to nonuniform intensity and signal voids across the image. Adding a linear increase in the phase to the RF pulses moves the signal voids to different values of off-resonance, therefore the acquisition of multiple images with different phase cycling schemes, and their subsequent combination (by means of maximum intensity projection [1], sum of squares [2], etc.) is an effective way to reduce the impact of these artifacts. In this abstract, we propose the non-linear pixelwise fit of the different phase cycles to the Freeman-Hill formula [3] that describes the bSSFP signal, in order to obtain the corrected signal amplitude together with a B0 map.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Joint Reconstruction for Phase-Cycled Balanced SSFP

Berkin Bilgic, Thomas Witzel, Himanshu Bhat, Lawrence L. Wald, Kawin Setsompop Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Harvard Medical School, Boston, MA, USA; Siemens Medical Solutions, Charlestown, MA, USA. INTRODUCTION: Balanced steady state free precession (bSSFP) is an SNR-efficient technique that has found widespread use in cardiac, ab...

متن کامل

Joint Reconstruction of Phase-Cycled Balanced SSFP with Constrained Parallel Imaging

Balanced SSFP is an SNR-e cient sequence with unique T /T contrast, but su ers from banding artifacts due to B sensitivity. These artifacts can be mitigated through RF phasecycling at a cost of signi cant increase in scan time. Here, we propose Joint L1-SPIRiT to jointly reconstruct highly accelerated/undersampled phase-cycled images and convert the di erent banding artifacts of these images in...

متن کامل

Banding Artifact Reduction in 2D CINE Balanced SSFP at 3.0 T Using Phase-Cycling and k-t BLAST

Introduction Balanced steady-state free precession (bSSFP) offers excellent signal-to-noise ratio (SNR) and consistent blood/myocardium contrast which renders 2D CINE bSSFP an ideal clinical choice for LV function assessment [1] at 1.5 T. bSSFP imaging remains challenging at 3.0 T due to its sensitivity to adverse off-resonance effects induced by strong field inhomogeneities at the heart-lung i...

متن کامل

PLANET: An ellipse fitting approach for simultaneous T1 and T2 mapping using phase‐cycled balanced steady‐state free precession

PURPOSE To demonstrate the feasibility of a novel, ellipse fitting approach, named PLANET, for simultaneous estimation of relaxation times T1 and T2 from a single 3D phase-cycled balanced steady-state free precession (bSSFP) sequence. METHODS A method is presented in which the elliptical signal model is used to describe the phase-cycled bSSFP steady-state signal. The fitting of the model to t...

متن کامل

Sensitivity and spatial specificity of multiple phase-cycled pass-band bSSFP fMRI at 9.4T

Introduction Pass-band bSSFP is a promising tool for high-resolution fMRI, but its signal sources have been unclear because there are two distinctive frequency bands, i.e., phaseinsensitive pass bands and phase-sensitive transition bands. Understanding the signal sources of bSSFP fMRI is important because different signal sources (T2 or T2) yield differential sensitivity and spatial specificity...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009