Volume phase holographic grating performance on the VIRUS-P instrument

نویسندگان

  • Joshua J. Adams
  • Gary J. Hill
  • Phillip J. MacQueen
چکیده

The Visible Integral-field Replicable Unit Spectrograph Prototype (VIRUS-P) has been in operation on the Harlan J Smith 2.7m Telescope at McDonald Observatory since October of 2006. The prototype was created to test the design and science capabilities of the full VIRUS instrument, wherein 150 copies of the spectrograph will be installed on the Hobby Eberly Telescope (HET). We here discuss the specialized test bench built to assess the blue optimized Volume Phase Holographic (VPH) grating performance. We also give lab and on-telescope efficiency measurements for three such gratings in the wavelength range 3400-6800Å. Two sources of stray light relevant to most spectrograph designs are also discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performances of volume phase holographic grating for space applications: study of the radiation effect.

The special properties of volume phase holographic gratings make them promising candidates for spectrometry applications where high spectral resolution, low levels of straylight, and low polarization sensitivity are required. Therefore it is of interest to assess the maturity and suitability of volume phase holographic gratings as enabling technologies for future space missions, with demanding ...

متن کامل

Diffracted wavefront measurement of a volume phase holographic grating at cryogenic temperature.

Flatness of the wavefront diffracted by grating can be mandatory for some applications. At ambient temperature, the wavefront diffracted by a volume phase holographic grating (VPHG) is well mastered by the manufacturing process and can be corrected or shaped by postpolishing. However, to be used in cooled infrared spectrometers, VPHGs have to stand and work properly at low temperatures. We pres...

متن کامل

ar X iv : a st ro - p h / 03 11 51 7 v 1 2 2 N ov 2 00 3 Cryogenic Tests of Volume - Phase Holographic Gratings : I . Results at 200 K

We present results from cryogenic tests of a Volume-Phase Holographic (VPH) grating at 200 K measured at near-infrared wavelengths. The aims of these tests were to see whether the diffraction efficiency and angular dispersion of a VPH grating are significantly different at a low temperature from those at a room temperature, and to see how many cooling and heating cycles the grating can withstan...

متن کامل

ar X iv : a st ro - p h / 06 09 06 9 v 1 4 Se p 20 06 Cryogenic tests of volume - phase holographic gratings : results at 100 K

We present results from cryogenic tests of Volume-Phase Holographic (VPH) gratings at ∼ 100 K. The aims of these tests are to see whether the diffraction efficiency as a function of wavelength is significantly different at a low temperature from that at room temperature and to see how the performance of a VPH grating is affected by a number of thermal cycles. We have completed 10 cycles between...

متن کامل

Citation for Published Item: Use Policy Cryogenic Tests of Volume-phase Holographic Gratings: Results at 100 K

We present results from cryogenic tests of Volume-Phase Holographic (VPH) gratings at ∼ 100 K. The aims of these tests are to see whether the diffraction efficiency as a function of wavelength is significantly different at a low temperature from that at room temperature and to see how the performance of a VPH grating is affected by a number of thermal cycles. We have completed 10 cycles between...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008