Influence of high insertion torque on implant placement: an anisotropic bone stress analysis.

نویسندگان

  • Bruno Salles Sotto-Maior
  • Eduardo Passos Rocha
  • Erika Oliveira de Almeida
  • Amilcar Chagas Freitas-Júnior
  • Rodolfo Bruniera Anchieta
  • Altair Antoninha Del Bel Cury
چکیده

The aim of this study was to evaluate the influence of the high values of insertion torques on the stress and strain distribution in cortical and cancellous bones. Based on tomography imaging, a representative mathematical model of a partial maxilla was built using Mimics 11.11 and Solid Works 2010 softwares. Six models were built and each of them received an implant with one of the following insertion torques: 30, 40, 50, 60, 70 or 80 Ncm on the external hexagon. The cortical and cancellous bones were considered anisotropic. The bone/implant interface was considered perfectly bonded. The numerical analysis was carried out using Ansys Workbench 10.0. The convergence of analysis (6%) drove the mesh refinement. Maximum principal stress (δmax) and maximum principal strain (εmax) were obtained for cortical and cancellous bones around to implant. Pearson's correlation test was used to determine the correlation between insertion torque and stress concentration in the periimplant bone tissue, considering the significance level at 5%. The increase in the insertion torque generated an increase in the δmax and εmax values for cortical and cancellous bone. The δmax was smaller for the cancellous bone, with greater stress variation among the insertion torques. The εmax was higher in the cancellous bone in comparison to the cortical bone. According to the methodology used and the limits of this study, it can be concluded that higher insertion torques increased tensile and compressive stress concentrations in the periimplant bone tissue.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of bone density on implant stability parameters and implant success: a retrospective clinical study

BACKGROUND The aim of the present clinical study was to determine the local bone density in dental implant recipient sites using computerized tomography (CT) and to investigate the influence of local bone density on implant stability parameters and implant success. METHODS A total of 300 implants were placed in 111 patients between 2003 and 2005. The bone density in each implant recipient sit...

متن کامل

Mathematical evaluation of the influence of multiple factors on implant stability quotient values in clinical practice: a retrospective study

OBJECTIVES The objective of this study is to mathematically evaluate the influence of multiple factors on implant stability quotient values in clinical practice. PATIENTS AND METHODS Resonance frequency analysis was performed at T1 (measured immediately at the time of implant placement) and at T2 (measured before dental restoration) in 177 patients (329 implants). Using a multivariate linear ...

متن کامل

Development and application of a direct method to observe the implant/bone interface using simulated bone

BACKGROUND Primary stability after implant placement is essential for osseointegration. It is important to understand the bone/implant interface for analyzing the influence of implant design on primary stability. In this study rigid polyurethane foam is used as artificial bone to evaluate the bone-implant interface and to identify where the torque is being generated during placement. METHODS ...

متن کامل

Correlation of Fractal Dimension Values with Implant Insertion Torque and Resonance Frequency Values at Implant Recipient Sites.

PURPOSE Fractal analysis is a mathematical method used to describe the internal architecture of complex structures such as trabecular bone. Fractal analysis of panoramic radiographs of implant recipient sites could help to predict the quality of the bone prior to implant placement. This study investigated the correlations between the fractal dimension values obtained from panoramic radiographs ...

متن کامل

Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.

BACKGROUND Clinical studies show promising outcomes with implants inserted at the time of extraction. However, this often results in an initial bone defect at the marginal region which preferably should heal for an optimal function. Therefore, monitoring of these implants is vital. PURPOSES The aims of this study were to determine the initial stability of implants placed into fresh extraction...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian dental journal

دوره 21 6  شماره 

صفحات  -

تاریخ انتشار 2010