Density dependence of respiratory input impedance re-evaluated with a head generator minimizing upper airway shunt.

نویسندگان

  • M Rotger
  • R Peslin
  • D Navajas
  • C Gallina
  • C Duvivier
چکیده

Total respiratory impedance was assessed from 4 to 30 Hz in ten normal subjects breathing air and a helium-oxygen gas mixture using two methods of applying pressure oscillations at the airway opening: 1) the conventional method where pressure is varied at the mouth: 2) the method recently developed by Peslin et al. (J Appl Physiol, 1985, 59, 1790-1795) in which pressure is varied both at the mouth and around the head to minimize transmural pressure across upper airway walls, and the corresponding artefact. When breathing air slightly lower resistances (p less than 0.05) and considerably higher inertances (p less than 0.001) were found using the head generator. Breathing helium-oxygen reduced respiratory resistance and its frequency dependence, as well as respiratory inertance very significantly (p less than 0.001), with minor differences between the changes seen with the two methods. In contrast, the changes in respiratory compliance were small, and not in the same direction, when pressure was varied at the mouth and around the head. It is concluded that the accuracy of the conventional method may be sufficient for diagnostic purposes in subjects without gross mechanical abnormalities, i.e. for early detection of mechanical abnormalities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of upper airway shunt on total respiratory impedance in infants.

When input impedance is determined by means of the forced oscillation technique, part of the oscillatory flow measured at the mouth is lost in the motion of the upper airway wall acting as a shunt. This is avoided by applying the oscillations around the subject's head (head generator) rather than at the mouth (conventional technique). In seven wheezing infants, we compared both techniques to es...

متن کامل

Input respiratory impedance to estimate airway hyperreactivity in children: standard method versus head generator.

We previously found that a significant underestimation of respiratory mechanical impedance (Zrs) at high frequency may result from the upper airway artefact in children, when pressure is directly varied at the mouth. To determine the importance of this artefact in estimating lung response to bronchomotor agents with the forced oscillation technique, input respiratory mechanical impedance was me...

متن کامل

Measurement of respiratory impedance by forced oscillation: comparison of the standard and head generator methods.

Physiological and clinical studies have shown that the standard method of measuring respiratory impedance by forced oscillation leads to less efficient control of the upper airway shunt effect than the head generator method. To test the effects of these two techniques in epidemiological studies, we compared, in a sample of 73 French agricultural workers, the values obtained with each method for...

متن کامل

Belgian Society for Pneumology

1. DuBois AB, Brody AW, Lewis DH, Burgess DF. Oscillation mechanics of lungs and chest in man. J Appl Physiol, 1956, 8, 587-594. 2. Michaelson ED, Grassman ED, Peters WR. Pulmonary mechanics by spectral analysis of forced random noise. J Clin Invest, 1975, 56, 1210-1230. 3. Peslin, Fredberg JJ. Oscillation mechanics of the respiratory system. In: Handbook of Physiology, Section 3, Vol. III. Mec...

متن کامل

Respiratory input and transfer mechanical impedances in patients with chronic obstructive pulmonary disease.

Total respiratory input (Zin) and transfer (Ztr) mechanical impedances were measured from 4-30 Hz in 9 patients with severe chronic obstructive pulmonary disease (COPD) and in 12 healthy subjects. Zin was obtained by applying a pressure input around the head to minimize transmural pressure across extrathoracic airway walls, and Ztr was obtained with a pressure input at the chest. In agreement w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 1 5  شماره 

صفحات  -

تاریخ انتشار 1988