Upper and lower tear menisci in the diagnosis of dry eye.

نویسندگان

  • Meixiao Shen
  • Jianhua Li
  • Jianhua Wang
  • Huixiang Ma
  • Chunyan Cai
  • Aizhu Tao
  • Yimin Yuan
  • Fan Lu
چکیده

PURPOSE To measure the upper and lower tear menisci in patients with aqueous tear deficiency (ATD) dry eye by real-time optical coherence tomography (OCT) and to determine the most effective meniscus variables for the diagnosis of dry eye. METHODS Eyes of 48 pre-screened ATD patients were compared with those of 47 healthy subjects. Upper and lower tear menisci were imaged simultaneously by real-time OCT immediately after blinking. The height, radius, and cross-sectional area of upper and lower tear menisci were obtained. RESULTS The tear meniscus radius, height, and cross-sectional area were significantly smaller in patients with dry eye than in healthy subjects (P < 0.01). The lower tear meniscus variables were higher than the upper menisci (P < 0.01) in normal subjects; however, no significant differences between menisci were found in ATD patients. In both groups, the upper and lower tear meniscus variables were strongly correlated with each other. Good dry eye diagnostic accuracies were obtained with cutoff values for an abnormal lower tear meniscus radius (LTMR) of 182 microm and a lower tear meniscus height (LTMH) of 164 microm. The LTMR diagnostic sensitivity and specificity were 0.92 and 0.87, respectively. The LTMH diagnostic sensitivity and specificity were 0.92 and 0.90. CONCLUSIONS Upper tear meniscus variables in ATD patients were assessed by real-time OCT. The tear meniscus was smaller in ATD patients than in healthy subjects. LTMR and LTMH may have potential in the diagnosis of ATD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tear meniscus volume in dry eye after punctal occlusion.

Purpose. To use optical coherence tomography (OCT) to evaluate the effect of punctal occlusion on tear meniscus volume in dry eye patients. Methods. Occlusion of both upper and lower puncta with collagen plugs was performed on one eye each in 20 dry eye patients and 20 normal subjects. The upper and lower tear menisci were imaged simultaneously by real-time OCT before punctal occlusion and on d...

متن کامل

Ultra-high resolution optical coherence tomography for monitoring tear meniscus volume in dry eye after topical cyclosporine treatment

PURPOSE This study was designed to determine the ability of ultra-high-resolution optical coherence tomography (UHR-OCT) to monitor tear meniscus volume after dry eye treatment with Restasis(®) (0.05% cyclosporine). METHODS UHR-OCT was used to image the upper and lower tear menisci (height and volume) in 14 consecutive dry eye patients at baseline. The treatment group was initiated on daily R...

متن کامل

Upper and lower tear menisci on contact lenses.

PURPOSE The purpose of this study was to measure upper and lower tear menisci on contact lenses using real time optical coherence tomography (OCT). METHODS Both eyes of 20 adapted contact lens wearers were imaged when they wore two types of silicone hydrogel lenses, balafilcon A on one eye and galyfilcon A on the other eye. The height, radius, and area of upper and lower tear menisci were obt...

متن کامل

Lower volumes of tear menisci in contact lens wearers with dry eye symptoms.

PURPOSE To investigate tear meniscus volumes during short-term lens wear by soft contact lens (SCL) wearers with dryness symptoms. METHODS Three groups of 20 subjects were recruited. Group 1 consisted of SCL wearers with self-reported dryness. Group 2 consisted of asymptomatic wearers. Group 3 was composed of asymptomatic non-lens wearers. Contact lenses were fitted on each eye, and both uppe...

متن کامل

Repeated measurements of dynamic tear distribution on the ocular surface after instillation of artificial tears.

PURPOSE To determine the repeatability of real-time optical coherence tomography (OCT) measurements of tear film thickness (TFT) and variables of tear film menisci. METHODS Forty eyes were imaged with a custom-built, real-time OCT to obtain heights, curvatures, and cross-sectional areas of upper and lower tear menisci simultaneously. The central TFT was indirectly determined as the difference...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 50 6  شماره 

صفحات  -

تاریخ انتشار 2009