VXD 3 : the SLD Vertex Detector Upgrade Based on a 307 MPixel CCD System

نویسنده

  • James E. Brau
چکیده

The SLD upgrade CCD vertex detector (VXD3) is described. Its 307 million pixels are assembled from 96 3.2 Mpixel CCDS of 13 cm2 each. The system has evolved from the pioneering CCD vertex detector VXD2, which has operated in SLD since 1992. The CCDS of VXD3 are mounted on beryllium ladders in three cylinders, providing three space point measurements along each track of about 5 microns resolution in all three co-ordinates. Significant improvements are achieved with VXD3 in impact parameter resolution (about a factor of two) and acceptance (-2070) . . through optimized geometry and reduced material. New readout electronics have been developed for this system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Performance of a New 307 Mpixel Ccd Vertex Detector*

During the past year, the SLD Collaboration completed construction and began operation of a new vertex detector (VXD3) with 307,000,000 CCD pixels. This upgrade will improve the SLD measurement of the polarization-enhanced forwardbackward asymmetry for band cquarks and the precision of the measurement of the b-fraction in hadronic Z decays and opens the possibility to observe ~~-m.ixing. Full s...

متن کامل

The SLD VXD3 Detector and Its Initial Performance*

The SLD collaboration completed construction of a new CCD vertex detector (VXD3) in January 1996 and started data taking in April 1996 with the new system. VXD3 is an upgrade of the original CCD vertex detector, VXD2, which had successfully operated in SLD for three years. VXD3 consists of 96 large area CCDs, each having 3.2 million 20pmx 20pm pixels. By reducing the detector material and lengt...

متن کامل

Test of the Flavor Independence Of

We compare the ratio of the strong coupling Q, measured in Z” --) b8 events to that measured in Z” -+ qq (q=u,d,a,c) in the SLD experiment at SLAC. Z” -* b6 events are identified with the aid of a precision silicon vertex detector by requiring that at least thiee charged tracks pass more than 3.017 from the Z” decay vertex. This method has an estimated efficieticy of 54% with a purity of 71%. J...

متن کامل

Direct Measurement of A b using Charged Kaons at the SLD Detector

We report a new measurement of A b using data obtained by SLD in 1997-98. This measurement uses a vertex tag technique, where the selection of a b hemisphere is based on the reconstructed mass of the bottom hadron decay vertex. The method uses the 3D vertexing capabilities of SLD's CCD vertex detector and the small and stable SLC beams to obtain a high b-event tagging efficiency and purity of 7...

متن کامل

Improved Estimate of the Occupancy by Beamstrahlung Electrons in the ILD Vertex Detector

The impact of the incoherent electron-positron pairs from beamstrahlung on the occupancy of the vertex detector (VXD) for the International Large Detector concept (ILD) has been studied, based on the standard ILD simulation tools. The occupancy was evaluated for two substantially different sensor technology in order to estimate the importance of the latter. The influence of an anti-DID field re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1995