A comparison of salivary testosterone measurement using immunoassays and tandem mass spectrometry.

نویسندگان

  • Keith M Welker
  • Bethany Lassetter
  • Cassandra M Brandes
  • Smrithi Prasad
  • Dennis R Koop
  • Pranjal H Mehta
چکیده

Enzyme immunoassays (EIAs) are widely used to measure salivary testosterone. However, little is known about how accurately different EIAs assess testosterone, partially because estimates across various EIAs differ considerably. We compared testosterone concentrations across EIAs of three commonly used manufacturers (DRG International, Salimetrics, and IBL International) to liquid chromatography tandem mass spectrometry (LC-MS/MS). Relative to EIAs from Salimetrics and IBL International, EIAs supplied by DRG International provided the closest approximation to LC-MS/MS testosterone concentrations, followed closely by EIAs from Salimetrics, and then IBL. Additionally, EIAs tended to inflate estimates of lower testosterone concentrations in women. Examining our results and comparing them to existing data revealed that testosterone EIAs had decreased linear correspondence with LC-MS/MS in comparison to cortisol EIAs. Overall, this paper provides researchers with information to better measure testosterone in their research and more accurately compare testosterone measurements across different methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Running head: TESTOSTERONE MEASUREMENT IMMUNOASSAYS 1 A comparison of salivary testosterone measurement using immunoassays and tandem mass spectrometry

Enzyme immunoassays (EIAs) are widely used to measure salivary testosterone. However, little is known about how accurately different EIAs assess testosterone, partially because estimates across various EIAs differ considerably. We compared testosterone concentrations across EIAs of three commonly used manufacturers (DRG International, Salimetrics, and IBL International) to liquid chromatography...

متن کامل

Measurement of testosterone by immunoassays and mass spectrometry in mouse serum, testicular, and ovarian extracts.

Accurate measurement of testosterone is important for reproductive endocrinology research, but the validity of direct (nonextraction) testosterone immunoassays, developed and validated for human serum, has not been appraised for application to mouse serum or steroidogenic tissue extracts. Testosterone was measured in serum and extracts of testis or ovary from male and female wild-type mice by 2...

متن کامل

Quantitative measurement of salivary testosterone in Korean adults by stable isotope-dilution liquid chromatographyelectrospray-tandem mass spectrometry.

Salivary testosterone levels in Korean adults were quantitatively measured for the first time by liquid chromatography-electrospray-tandem mass spectrometry (LC ESI MS/MS). Salivary testosterone was separated on a multiple reaction monitoring (MRM) chromatogram within 7 min. The LC ESI MS/MS assay was validated over the linearity range of 0.01-2.00 ng/ml (r=0.99987) using testosterone-d(3) as a...

متن کامل

Inter-method comparison of salivary cortisol measurement

Background: Salivary cortisol is increasingly used in the diagnostic work-up of suspected Cushing’s disease as well as in stress research. In this study, the agreement of different methods for salivary cortisol measurement was assessed. Methods: Saliva samples from five healthy volunteers were distributed to three routine clinical chemistry laboratories. As a reference, all samples were also an...

متن کامل

Rapid determination of serum testosterone by liquid chromatography-isotope dilution tandem mass spectrometry and a split sample comparison with three automated immunoassays.

OBJECTIVES To develop a rapid convenient-to-implement high performance liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS) method for determination of serum testosterone concentration in routine clinical laboratories. METHODS Following extraction by organic solvents, an Agilent 1200 Series HPLC system coupled to an API 5000 mass spectrometer equipped with an atmospher...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Psychoneuroendocrinology

دوره 71  شماره 

صفحات  -

تاریخ انتشار 2016