Correlation between bone quality evaluated by cone-beam computerized tomography and implant primary stability.

نویسندگان

  • Young-Dai Song
  • Sang-Ho Jun
  • Jong-Jin Kwon
چکیده

PURPOSE To examine the relationship between bone quality, as evaluated by cone-beam computerized tomography (CBCT), and implant primary stability, as measured by resonance frequency analysis (RFA). MATERIALS AND METHODS A preliminary clinical study was conducted in which implant placements were scheduled for 20 patients. The CT scan was obtained after initial drilling, and implant stability was measured with the Osstell Mentor instrument before flap closure. With CBCT, CT numbers of surrounding bone were calculated and the thickness of compact bone was measured at the buccal, lingual, mesial, and distal surfaces of each implant. The correlations between CT numbers and implant stability quotients (ISQs) and between compact bone thickness and ISQs were tested with the Pearson correlation coefficient. RESULTS Overall, 61 implants were examined in 20 patients. The statistics showed that the CT numbers and the thickness of compact bone had strong correlations to ISQs (P < .025). CONCLUSION CT scanning was suggested to be effective for evaluating bone quality and predicting initial implant stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی رابطه بین دانسیته استخوانی حاصل ازCone-Beam Computed Tomography با میزان ثبات اولیه ایمپلنت دندانی

Introduction & Objective: Study of bone quality before treatment is very important. The aims of this study were to assess bone quality with density values obtained by cone-beam computed tomography (CBCT) and to determine the correlations between bone density and primary stability of dental implants. Materials & Methods: In this experimental in vitro study 32 implants were inserted into fresh ...

متن کامل

The Accuracy of Cone-beam Computerized Tomography Linear Measurements in Human Dry Mandible

Background & Aims: The aim of this study was to evaluate the accuracy of Cone-beam Computerized Tomography (CBCT) linear measurements in dry mandibles by comparing them with direct measurements. Methods: Two human dry mandibles were used in this study. Thirteen sites were selected on each mandible. Specimens were scanned by CBCT and linear measurements were made using Planmeca Romexis 2.3.0.R s...

متن کامل

Biomechanical evaluation of oversized drilling technique on primary implant stability measured by insertion torque and resonance frequency analysis

BACKGROUND This study evaluated the influence of implant site preparation depth on primary stability measured by insertion torque and resonance frequency analysis (RFA). MATERIAL AND METHODS Thirty-two implant sites were prepared in eight veal rib blocks. Sixteen sites were prepared using the conventional drilling sequence recommended by the manufacturer to a working depth of 10mm. The remain...

متن کامل

Correlation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)

Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...

متن کامل

Relation between bone density and primary implant stability.

AIMS This study aims to relate bone density in Hounsfield units (Hu) with the primary implant stability measured by insertion torque (Ncm) and resonance frequency analysis (ISQ). MATERIALS AND METHODS Ten patients were included in this study. A total of 54 implant sites were provided from 10 computerized tomography scans. The computerized tomography scan was used for the preoperative evaluati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 2009