Simplified fluorometric assay for diphenylhydantoin in plasma.
نویسندگان
چکیده
The fluorometric benzophenone procedure for diphenylhydantoin has been simplified by eliminating the need for preliminary extraction of plasma with an organic solvent. Assays are done directly on 0.2 ml of plasma by treating it with alkaline permanganate to form benzophenone, extracting the benzophenone with heptane, and then shaking the heptane layer with sulfuric acid and measuring the fluorescence of the acid layer. The assay is highly reproducible, and adequately sensitive to detect 1 mug of the drug per milliliter of plasma. Fluorometric and gas-liquid chromatographic assays of 154 plasmas gave results that were not significantly different, even in the presence of phenobarbital, other barbiturates and anticonvulsant drugs, or of various tranquilizers and other commonly used drugs. The assay is rapid, the unit cost per assay low.
منابع مشابه
Assay of phenytoin: adaptation of "EMIT" to the centrifugal analyzer.
7. Booker, H. E., and Darcey, B. A., Enzymatic ixnmunoassay vs. gas_liquid chromatography for determination of phenobarbital and diphenylhydantoin in serum. Clin. Chem. 21, 1766 (1975). 8. Wallace, J., Biggs, J., and Dahl, E. V., Determination of diphenyihydantoin by ultraviolet spectrophotometry. Anal. Chem. 37,410 (1965). 9. Dill, W. A., Chucot, L., Chang, T., and Glazko, A. J., Simplified be...
متن کاملFluorometric assay of diphenylhydantoin in plasma or whole blood.
A highly sensitive assay procedure for 5,5-diphenylhydantoin (DPH) involves oxidation with alkaline permanganate to form benzophenone. This is then extracted with heptane, allowed to react with concentrated sulfuric acid, and the fluorescence of the reaction product is measured. The procedure appears to be fairly specific for DPH; 5.(p.hyd roxyphenyl)-5.phenylhydantoin (a DPH metabolite), pheno...
متن کاملNew Usage of a Fluorometric Method to Assay Antioxidant Activity in Plant Extracts
In the present study, an oxidative conversion of non-fluorescent dichlorofluoroscein (LDCF) to fluorescent dichlorofluoroscein (DCF) was used for detection of antioxidant properties of plant extracts. The rate of the reaction was followed by monitoring the formation of DCF as a function of time. The antioxidant assay was carried out for different concentrations of gallic acid, Salvia ...
متن کاملMeasurement of diphenylhydantoin in 0.1-ml plasma samples: gas chromatography and radioimmunoassay compared.
Concentrations of diphenylhydantoin in 364 plasma samples have been measured both by radioimmunoassay and with a recently developed gas-chromatographic method, which requires only 0.1 ml of plasma per determination. There was an excellent correlation between values obtained by the two methods (r = 0.986), and in only 11 plasma samples did the results differ by more than 20%. Of the investigated...
متن کاملNonspecific interferences in the fluorometric determination of plasma cortisol.
The popular Mattingly [J. Gun. Pathol. 15, 374 (1962)] fluorometric assay for plasma cortisol is shown to give rise to falsely high values when performed with the recommended optical arrangement. By exciting at 470 nm, however, results are obtained that correlate well (r = 0.972) with those of competitive protein binding. The source of the interference is not identified, but it is related to bo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 22 6 شماره
صفحات -
تاریخ انتشار 1976