Pre-excimer laser and post-excimer laser refractive surgery measurements of scotopic pupil diameter using 2 pupillometers.

نویسندگان

  • Leopoldo Spadea
  • Daniele Giammaria
  • Roberto Ferrante
  • Emilio Balestrazzi
چکیده

PURPOSE To compare a digital infrared pupillometer with a handheld light amplification pupillometer for measuring scotopic pupil size and to evaluate if the postoperative refractive changes of the cornea can influence pupil measurements. DESIGN Prospective noncomparative interventional case series. PARTICIPANTS One hundred eyes, 50 myopic (mean spherical equivalent [SE] refraction [+/- standard deviation], -4.32+/-2.44 diopters [D]) and 50 hyperopic (mean SE refraction, +2.95+/-0.99 D), of 50 otherwise healthy subjects underwent photorefractive keratectomy or LASIK. INTERVENTION The preoperative and postoperative scotopic pupil sizes were measured by 2 examiners (E1, E2) with both a handheld light amplification pupillometer (Colvard, Oasis Medical, Glendora, CA) and a digital infrared pupillometer (Eye World Pupillometer [EWP], Oculus Keratograph, Oculus Opikgerate GmbH, Wetzlar, Germany). The agreement and interrater repeatability were determined using the comparison method described by Bland and Altman. The paired Student's t test was used to evaluate the difference between the preoperative and postoperative measurements. MAIN OUTCOME MEASURES Scotopic pupil diameter, topographic corneal refractive power, uncorrected visual acuity (VA), best spectacle-corrected VA, and manifest spectacle refraction. RESULTS The preoperative mean scotopic pupil diameter was 6.12+/-0.90 mm with the EWP and 6.18+/-0.91 mm with the Colvard. After the surgery, mean SE refractions were -0.22+/-0.98 D (myopic patients) and +0.19+/-0.40 D (hyperopic patients). Postoperative mean scotopic pupil diameters were 6.12+/-0.89 mm (EWP) and 6.17+/-0.90 mm (Colvard). There was no statistically significant difference between preoperative and postoperative mean scotopic pupil sizes in either patient group. The limits of agreement between the 2 devices ranged from 2.24 mm (E1) to 2.12 mm (E2) preoperatively and from 2.27 mm (E1) to 2.08 mm (E2) postoperatively. The coefficient of interrater repeatability ranged from 0.56 mm (EWP) to 1.12 mm (Colvard) preoperatively and from 0.62 mm (EWP) to 1.14 mm (Colvard) postoperatively. CONCLUSIONS The digital infrared pupillometer showed better preoperative and postoperative repeatability than the handheld light amplification pupillometer. In the present study, a mean correction of <3 D of the corneal refractive power did not seem to modify the preoperative scotopic pupil size measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

308-nm excimer laser plus topical calcipotriol in the treatment of vitiligo; A single blind randomized clinical study

Background: There is a large variety of therapeutic agents for the treatment of vitiligo, but it still remains a challenge. Narrow-band UVB phototherapy and 308-nm excimer laser have been shown to be safe and effective for the treatment of vitiligo. Topical calcipotriol has recently been reported to enhance the efficacy of phototherapy, especially 8-methoxypsoralen plus UVA (PUVA). The goal of ...

متن کامل

Excimer laser 6th generation: state of the art and refractive surgical outcomes

After nearly three decades of innovation in excimer laser, today we are presented with a state of the art generation targeting minimally invasive refractive surgery with high speed laser, faster trackers, pupil monitoring systems and better customization profiles. These systems are capable of delivering better treatments with less induced postoperative high order aberrations. The results report...

متن کامل

Innovations in Excimer Laser Refractive Technology – Focus on the WaveLight® EX500 Excimer Laser System

Excimer laser refractive surgery aims to correct lower order eye aberrations such as myopia, astigmatism and hyperopia by altering the shape of the corneal curvature through the ablation of corneal tissue. Early excimer systems were associated with concerns over post-operative complications, such as night-time driving problems, glare and halos. Furthermore, it was difficult to prevent or treat ...

متن کامل

The 308-nm xenon chloride excimer laser in combination with topical calcipotriol in the treatment of vitiligo

Background: Treatment of vitiligo remains an attractive topic and several therapies with varying degrees of success have been used. The aim of this study was to find out whether the combination of topical calcipotriol and excimer laser increases the efficacy of therapy compared to excimer laser alone. Methods: Twenty eight patients in two groups were treated with 308nm excimer laser alone (14 p...

متن کامل

Comparison of measurement of pupil sizes among the colvard pupillometer, procyon pupillometer, and NIDEK OPD-scan.

PURPOSE To compare pupil sizes measured with the Colvard pupillometer, Procyon pupillometer, and NIDEK OPD-Scan. METHODS Pupil diameter was measured in 90 consecutive eyes from 55 patients under mesopic and scotopic light conditions with all three instruments. RESULTS The mean scotopic pupil diameter was 6.3+/-0.98 mm with the Colvard pupillometer and 6.45+/-1.01 mm with the Procyon pupillo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ophthalmology

دوره 112 6  شماره 

صفحات  -

تاریخ انتشار 2005