Retrospective analysis of mode survival, reliability of atrial sensing and incidence of atrial tachyarrhythmias in 307 single-lead VDD pacemaker patients.

نویسندگان

  • Igor Zupan
  • Luka Lipar
  • David Zizek
  • Wim Boute
  • Masa Vidmar
  • Tone Gabrijelcic
  • Peter Rakovec
  • Ales Brecelj
چکیده

AIMS The aim of this retrospective analysis was to investigate VDD mode survival, development of atrial tachyarrhythmias (AT), and long-term atrial sensing performance of VDD pacing systems. METHODS AND RESULTS We implanted single-lead VDD pacemakers in patients with isolated atrioventricular block and performed a retrospective analysis of 307 patients who had their devices implanted between May 1994 and September 2001. In 39 patients (12.7%), the pacing mode had to be reprogrammed to a single-chamber ventricular pacing mode, mostly due to permanent AT. In 16 of these patients, the atrial sensing safety margin was less than 150%. The atrial sensing safety margin was insufficient, i.e. less than 100% in only seven patients. Although only 12 (3.9%) of the patients had a history of paroxysmal AT at the time of pacemaker implantation, 200 (65%) patients presented with AT during follow-up. The mean AT burden at the last follow-up was 2.5%. CONCLUSION These data illustrate that single-lead VDD pacemakers can be applied without serious complications in a highly selected group of patients. Our main concern is the development of AT in a large part of our population. Over a 10-year period, two thirds of our patients presented with AT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Safety and effectiveness of single-lead VDD pacing].

INTRODUCTION AND OBJECTIVES Single-lead VDD pacing provides the physiological benefits of atrioventricular synchrony with the convenience of a single-lead system. However, concern remains about the method's safety and effectiveness. METHOD In total, 700 patients with single-lead VDD pacemakers were evaluated retrospectively. The following parameters were recorded: age, sex, etiology, the symp...

متن کامل

Immediate and mid-term safety and efficacy of single lead VDD pacemakers for patients with atrioventricular block and normal sinus node function--a single centre experience.

INTRODUCTION Single lead atrial synchronous ventricular pacing (VDD) is increasingly being used in place of conventional dual chamber pacing (DDD) for patients with atrioventricular block and preserved sinus node function. Compared to the latter, VDD pacemakers provide similar haemodynamic benefits derived from atrial synchronous pacing, with the added benefit of an easier implant procedure. ...

متن کامل

Long-term outcome in patients receiving permanent pacemaker implantation for atrioventricular block

A permanent pacemaker (PPM) with dual chamber pacing (DDD) offers atrioventricular synchronization for patients with atrioventricular block (AVB). Single lead atrial synchronous ventricular pacing mode (VDD) is an alternative, but there are concerns about its efficacy and risk of atrial undersensing. Whether VDD can be a good alternative in patients with AVB remains unknown. The aim of the pres...

متن کامل

Stable Atrial Sensing on Long-Term Follow Up of VDD Pacemakers

BACKGROUND The hemodynamic advantages of maintaining AV synchrony through AV synchronous pacing are widely known as compared to single chamber pacing. DDD pacemaker implantation entails higher cost and is technically more challenging than the VDD pacemaker. METHODS Seventy one patients underwent VDD lead (Biotronik GmbH, St. Jude Medical and Medtronic Inc.) implantation at KEM hospital, Mumba...

متن کامل

The Improvement of the Atrial Flutter Rhythm upon the Removal of the Infected Permanent Pacemaker Lead

Pacemaker infection has multiple risk factors. Its presentation is most often similar to infected endocarditis and the diagnosis is made through studying blood cultures. Transesophageal echocardiography can confirm the diagnosis. The most common microorganisms are staphylococcus speciesis. As a matter of fact, complete pacemaker removal appears to be the only definite treatment. We presented a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 8 10  شماره 

صفحات  -

تاریخ انتشار 2006