X-ray mass attenuation coefficient of silicon: theory versus experiment.
نویسندگان
چکیده
We compare new experimental x-ray total mass attenuation coefficients of silicon obtained with the x-ray extended-range technique (XERT) from 5 to 20 keV with theoretical calculations and earlier experimental measurements over a 5 to 50 keV energy range. The accuracy of between 0.27% and 0.5% of the XERT data allows us to probe alternate atomic and solid state wave function calculations and to test dominant scattering mechanisms. Discrepancies between experimental results and theoretical computations of the order of 5% are discussed in detail. No single theoretical computation is currently able to reproduce the experimental results over the entire 5 to 50 keV energy range investigated.
منابع مشابه
Investigation of the Mass Attenuation Coefficient for Composites Containing Nano and Micro-Particles of Copper Oxide against Diagnostic X-ray
Radiation protection and the selection of suitable materials to reduce radiation effects is one of the important branches of medical science and radiation. In this paper, the mass attenuation coefficients, half value layer thicknesses and thicknesses of 0/5 mm lead of polyvinyl chloride (PVC) composites containing Nano and micro-particles of copper oxide are calculated using experimental method...
متن کاملMeasurement of the x-ray mass attenuation coefficient and the imaginary part of the form factor of silicon using synchrotron radiation
We used the x-ray extended-range technique to measure the x-ray mass attenuation coefficients of silicon with an accuracy between 0.27% and 0.5% in the 5 keV220 keV energy range. Subtraction of the x-ray scattering contribution enabled us to derive the corresponding x-ray photoelectric absorption coefficients and determine the absolute value of the imaginary part of the atomic form factor of si...
متن کاملApplication of characteristic X-rays to measure linear attenuation coefficient of nano-composites used in shielding
Using of X-rays in different industries and especially in medical application is increasing. In this regard, designing of light and efficient protective material based on polymeric nanocomposites and precise study of the effect of adding nanoparticles with different sizes on the X-ray attenuation is necessary. In this study the epoxy nanocomposites with different percentages of copper oxide nan...
متن کاملX-ray extended-range technique for precision measurement of the X-ray mass attenuation coefficient and Im(f ) for copper using synchrotron radiation
We reconsider the long-standing problem of accurate measurement of atomic form factors for fundamental and applied problems. We discuss the X-ray extended-range technique for accurate measurement of the mass attenuation coefficient and the imaginary component of the atomic form factor. Novelties of this approach include the use of a synchrotron with detector normalisation, the direct calibratio...
متن کاملMeasurement of the x-ray mass attenuation coefficient of copper using 8.85–20 keV synchrotron radiation
This work presents the x-ray extended range technique for measuring x-ray mass attenuation coefficients. This technique includes the use of multiple foil attenuators at each energy investigated, allowing independent tests of detector linearity and of the harmonic contributions to the monochromated synchrotron beam. Measurements over a wide energy range allow the uncertainty of local foil thickn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physical review letters
دوره 90 25 Pt 1 شماره
صفحات -
تاریخ انتشار 2003