Evaluation of a Virtual Refrigerant Charge Sensor

نویسندگان

  • Woohyun Kim
  • James E. Braun
چکیده

The primary goal of work described in this paper is to evaluate and enhance a virtual refrigerant charge sensor, developed in a previous study. The virtual refrigerant charge sensor algorithm employs low-cost and non-invasive measurements (i.e. surface mounted temperature measurements) to estimate refrigerant charge level for packaged air conditioning systems. It can be embedded within a portable device (i.e. a PDA) for a technician’s use in the field or permanently installed on units. Based on the evaluations for a wide range of systems and conditions, the virtual charge sensor was found to work well in estimating refrigerant charge for systems that do not utilize accumulators when using the original default parameters. For systems with accumulators, however, the parameters needed to be improved. A new method for determining default parameters was developed that depends on three elements: liquid line length, rated subcooling, and rated charge. The liquid line length is particularly important because a substantial amount of refrigerant is stored as liquid. The parameters decreased the errors between the actual and predicted charge. Even better performance was achieved for the virtual refrigerant charge sensor when the improved parameters were tuned, minimizing the errors by using test data and linear regression. Overall, the enhanced method provided estimates of refrigerant charge that were within 10 percent of the actual charge over a wide range of operating conditions for a number of different systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extension of a Virtual Refrigerant Charge Sensor

The primary goal of the work described in this paper was to evaluate and extend a virtual refrigerant charge sensor (VRC) for determining refrigerant charge for equipment having variable-speed compressors and fans. To evaluate the accuracy of the VRC, data were first collected from previous laboratory tests for different systems and over a wide range of operating conditions. In addition, new la...

متن کامل

Fault Detection And Diagnosis For Air Conditioners And Heat Pumps Based On Virtual Sensors

Kim, Woohyun. Ph.D., Purdue University, December 2013. Fault Detection and Diagnosis for Air Conditioners and Heat Pumps based on Virtual Sensors. Major Professor: James E. Braun, School of Mechanical Engineering. The primary goal of this research is to develop and demonstrate an integrated, on-line performance monitoring and diagnostic system with low cost sensors for air conditioning and heat...

متن کامل

Evaluation of Virtual Refrigerant Mass Flow Sensors

Refrigerant mass flow rate is an important measurement for monitoring equipment performance and enabling fault detection and diagnostics. However, a traditional mass flow meter is expensive to purchase and install. A virtual refrigerant mass flow sensor (VRMF) uses a mathematical model to estimate flow rate using low-cost measurements and can potentially be implemented at low cost. This study e...

متن کامل

Control Method Of Circulating Refrigerant Amount For Heat Pump System

A heat pump system requires proper refrigerant charge amount. Once refrigerant is charged into a heat pump system, its charge amount is fixed. For this reason, prediction of optimal refrigerant charge amount is very important in order to yield best performance. Too low charge amount degrades capacity of heat pump. On the other hand, excessive charge amount decreases coefficient of performance (...

متن کامل

Effect of Refrigerant Charge, Compressor Speed and Air Flow Through the Evaporator on the Performance of an Automotive Air Conditioning System

Using identical mechanical hardware used in an automobile, a stationary test bench has been developed for an automotive air conditioning system (AACS). However, a number of additional sensors have been used in the system for an accurate assessment of its performance. The steady state performance of the system has been investigated for three independent variables, namely the refrigerant charge l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014