Occupational exposures and determinants of ultrafine particle concentrations during laser hair removal procedures

نویسندگان

  • Emily J. Eshleman
  • Mallory LeBlanc
  • Lisa B. Rokoff
  • Yinyin Xu
  • Rui Hu
  • Kachiu Lee
  • Gary S. Chuang
  • Gary Adamkiewicz
  • Jaime E. Hart
چکیده

BACKGROUND Occupational exposures to ultrafine particles in the plume generated during laser hair removal procedures, the most commonly performed light based cosmetic procedure, have not been thoroughly characterized. Acute and chronic exposures to ambient ultrafine particles have been associated with a number of negative respiratory and cardiovascular health effects. Thus, the aim of this study was to measure airborne concentrations of particles in a diameter size range of 10 nm to 1 μm in procedure rooms during laser hair removal procedures. METHODS TSI Model 3007 Condensation Particle Counters were used to quantify the particle count concentrations in the waiting and procedure rooms of a dermatology office. Particle concentrations were sampled before, during, and after laser hair removal procedures, and characteristics of each procedure were noted by the performing dermatologist. RESULTS Twelve procedures were sampled over 4 days. Mean ultrafine particle concentrations in the waiting and procedure rooms were 14,957.4 particles/cm3 and 22,916.8 particles/cm3 (p < 0.0001), respectively. Compared to background ultrafine particle concentrations before the procedure, the mean concentration in the procedure room was 2.89 times greater during the procedure (p = 0.009) and 2.09 times greater after the procedure (p = 0.007). Duration of procedure (p = 0.006), body part (p = 0.013), and the use of pre-laser lotion/type of laser (p = 0.039), were the most important predictors of ultrafine particle concentrations. Use of a smoke evacuator (a recommended form of local exhaust ventilation) positioned at 30.5 cm from the source, as opposed to the recommended 1-2 in., lowered particle concentrations, but was not a statistically significant predictor (p = 0.49). CONCLUSIONS Laser hair removal procedures can generate high exposures to ultrafine particles for dermatologists and other individuals performing laser hair removal, with exposure varying based on multiple determinants.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical smoke and ultrafine particles

BACKGROUND Electrocautery, laser tissue ablation, and ultrasonic scalpel tissue dissection all generate a 'surgical smoke' containing ultrafine (<100 nm) and accumulation mode particles (< 1 mum). Epidemiological and toxicological studies have shown that exposure to particulate air pollution is associated with adverse cardiovascular and respiratory health effects. METHODS To measure the amoun...

متن کامل

Ultrafine and respirable particles in an automotive grey iron foundry.

Ultrafine particle number and respirable particle mass concentrations were measured throughout an automotive grey iron foundry during winter, spring and summer using a particle concentration mapping procedure. Substantial temporal and spatial variability was observed in all seasons and attributed, in part, to the batch nature of operations, process emission variability and frequent work interru...

متن کامل

Estimation of health risks and safety margins due to inhalation of ultrafine particles and nanoparticles in selected occupational, consumer and environmental settings

Nanoparticles exhibit properties different from those of the same bulk materials leading to unknown toxicological implications that have evoked concern for (1) occupational, (2) consumer and (3) environmental safety. The current work utilizes epidemiological and toxicological data for screening level assessment of these risks using various suggested health relevant dose metrics (mass, particle ...

متن کامل

Ultrafine Particle (UFP) Exposures in an Aluminium Smelter: Soderberg vs. Prebake Potrooms

The objectives of this work were to evaluate ultrafine particle (UFP) exposures during aluminium smelting in Soderberg and prebake potrooms. Particle concentrations were monitored using the P-Trak 8525 and aerosol particle size distributions were monitored with the electrical low pressure impactor (ELPI). UFP samples were analyzed for chemical composition by transmission electron microscopy (TE...

متن کامل

Palpable Purpura: An Uncommon Side Effect of Alexandrite Laser Hair Removal

A 40-year old woman was visited at our clinic with a history of palpable purpura appearing after alexandrite laser (Apogee 5500 Alex, 15mm spot shot, 755 nm wave length, 18 j/cm2 fluence) hair removal. The skin lesions were located bilaterally on the lower extremity (Figure1). Other physical examinations were unremarkable. The patient had no history of taking medications, underlying systemic di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2017