A Position Sensitive Detector for 1 - 10 MeV Gamma RaysJoel

نویسندگان

  • Joel G. Rogers
  • Christian Moisan
  • Ami Altman
  • Yao Xiao
چکیده

A position sensitive detector for 9 MeV gamma rays has been developed as part of a contraband detection system for airports. The system images contraband, such as explosives or drugs, in a geometry similar to medical x-ray computed tomography. A point source of gamma rays shines through an unknown object. Transmission projections of the areal density of detected gamma rays are reconstructed into a 3D image, which shows the presence of concealed contraband inside the object. The image quality depends critically on the spatial resolution of the gamma ray detector. The existing detector is a modiied version of ones developed by CTI for medical PET imaging with 0.511 MeV gamma rays. An initial prototype detector was characterized by exposing it to 9 MeV gamma rays from a 252 Cf + Ni source. Projection images of a simple phantom object show that the detector is capable of faithful imaging at 9 MeV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ar X iv : a st ro - p h / 04 12 04 7 v 1 2 D ec 2 00 4 Development of an advanced Compton camera with gaseous TPC and scintillator

A prototype of the MeV gamma-ray imaging camera based on the full reconstruction of the Compton process has been developed. This camera consists of a micro-TPC that is a gaseous Time Projection Chamber (TPC) and scintillation cameras. With the information of the recoil electrons and the scattered gamma-rays, this camera detects the energy and incident direction of each incident gamma-ray. We de...

متن کامل

Conceptual Design and Simulation of Alpha-Beta Detector for Surface Contamination Measurements

The radioactive contamination measurement is essential in nuclear facilities. Monitoring of low level alpha and beta contamination is possible using light detectors high efficiency. Due to the fact that many detectors canchr('39')t simultaneously discriminate alpha, beta and gamma rays; among existing methods, phoswich detectors would be appropriate option to measure different radioactive conta...

متن کامل

Gamma ray polarimetry using a position sensitive germanium detector

Imaging gamma-ray detectors make sensitive polarimeters in the Compton energy regime by measuring the scatter direction of gamma-rays. The principle is to capitalize on the angular dependence of the Compton scattering cross section to polarized gamma rays and measure the distribution of scatter directions within the detector. This technique is effective in a double-sided germanium detector betw...

متن کامل

Evaluation of a Compton scattering camera using 3-D position sensitive CdZnTe detectors

A CZT Compton Camera (CCC) is being built using two three-dimensional (3-D) position-sensitive CZT detectors. Expected system performance was analyzed by analytical and Monte Carlo approaches. Based on the measurement of detector energy and position resolution, the expected angular resolution is &33 and &23 for a $303 FOV for 511 keV and 1 MeV c-rays, respectively. The intrinsic e$ciency for a ...

متن کامل

Gamma Ray Energy Measurement using the Multiple Compton Technique

Modern developments in detector and electronics technology now enable a new generation of gamma ray detectors based on recording each and every energy loss associated with an incident gamma ray. The energy of an incident gamma ray is determined by measuring the positions of the first three interactions, and the energy loss of the first two. The direction of the incident gamma ray is restricted ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997