A multi-site study for detection of the factor V (Leiden) mutation from genomic DNA using a homogeneous invader microtiter plate fluorescence resonance energy transfer (FRET) assay.

نویسندگان

  • M Ledford
  • K D Friedman
  • M J Hessner
  • C Moehlenkamp
  • T M Williams
  • R S Larson
چکیده

The goal of this multicenter study was to evaluate the second-generation Invader technology for detecting the factor V (Leiden) mutation directly from genomic DNA of different sample types. Invader assay results were compared with polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) or allele-specific PCR (AS-PCR) analysis. The Invader assay is a PCR-independent methodology that uses a microtiter plate format. In the assay, a specific upstream Invader oligonucleotide and a downstream probe hybridize in tandem to a complementary DNA template and form a partially overlapping structure. The Cleavase VIII enzyme recognizes and cuts this structure to release the 5' flap of the probe. This flap then serves as an Invader oligonucleotide to direct cleavage of a fluorescence resonance energy transfer (FRET) probe in a second invasive cleavage reaction. Cleavage of this FRET probe results in the generation of a fluorescent signal. The results of the Invader assay were 99.5% concordant with the PCR-based methods. Of the 372 samples tested once, only two gave discordant results (one from operator error and one from unknown causes), but were concordant on retesting. These results indicate that a simple microtiter plate-based Invader assay can reliably genotype clinical patient samples for the factor V (Leiden) point mutation directly from genomic DNA without prior target amplification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Genotyping of factor V G1691A (Leiden) without the use of PCR by invasive cleavage of oligonucleotide probes.

BACKGROUND The factor V G1691A Leiden (FVL) mutation is the most common known hereditary risk factor for venous thrombosis. METHODS Third Wave Technologies, Inc. (Madison, WI) has developed a new microtiter plate-based assay that does not require PCR, restriction digestion, or gel electrophoresis. This technology system, termed the Invader(TM) assay, utilizes a 5' "invading" oligonucleotide a...

متن کامل

Rapid detection of the factor V Leiden (1691 G > A) and haemochromatosis (845 G > A) mutation by fluorescence resonance energy transfer (FRET) and real time PCR.

A rapid method based on fluorescence resonance energy transfer (FRET) and real time polymerase chain reaction (PCR) was used to identify the haemochromatosis genotype in 112 individuals and the factor V genotype in 134 individuals. The results were compared with conventional methods based on restriction enzyme digestion of PCR products. The two methods agreed in 244 of the 246 individuals; for ...

متن کامل

Highly Sensitive FRET-Based Fluorescence Immunoassay for Detecting of Aflatoxin B1 Using Magnetic/Silica Core-Shell as a Signal Intensifier

Background: Recently, some new nanobiosensors using different nanoparticles or microarray systems for detection of mycotoxins have been designed . However, rapid, sensitive and early detection of aflatoxicosis would be very helpful to distinguish high-risk persons. Objectives: We report a highly sensitive competitive immunoassay using magnetic/silica core shell as a signal intensifier for the d...

متن کامل

Frequency of factor V Leiden (G1691A) and prothrombin (G20210A) polymorphisms in Population of Kerman Province, Iran

Background & Aims:Thromboembolism is an acute cardiovascular disease that ranges from clinically unimportant to massive embolism. Both acquired and hereditary risk factors contribute to the disease.
We aimed to determine the prevalence of two hereditary predisposing factor of the disease, prothrombin G20210A and factor V Leiden (G1691A) polymorphisms, in Kerman population.<br /...

متن کامل

Real-time fluorescence genotyping of factor V Leiden during rapid-cycle PCR.

A single-step method for factor V Leiden genotyping is presented that uses rapid-cycle PCR and simultaneous fluorescence analysis with resonance energy transfer probes. A fragment of the factor V gene containing the mutation is amplified asymmetrically through use of a primer labeled with Cy5 in the presence of a 3'-fluorescein-labeled probe that covers the mutation site. When the fluorescein p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of molecular diagnostics : JMD

دوره 2 2  شماره 

صفحات  -

تاریخ انتشار 2000