Automatic Tracking of Local Myocardial Motion by Correlation Weighted Velocity Method
نویسندگان
چکیده
In this paper, we propose a new method for automatically tracking the motion of local region in left ventricular myocardium by means of ultrasonic pulsed Doppler signal. This method consists of a velocity detection procedure based on correlation weighted mean instantaneous velocity and a motion tracking procedure employing a myocardial elastic model. Most of ultrasonic pulsed Doppler signals observed in clinical diagnosis contain considerable amount of speckle noise, which causes detection error of velocity. The detection error is accumulated in the motion tracking procedure and yields obviously incorrect motion trajectory. The procedure of correlation weighted mean velocity is aimed to reduce the velocity detection error, and the myocardial elastic model is used to avoid the accumulation of the error to keep track of the motion of the myocardium in reasonable accuracy. The result of evaluation test shows that this method is able to improve the accuracy of tracking approximately 40 % relative to a conventional CLS approach.
منابع مشابه
Semi-Automatic Noninvasive Tracking of Local Myocardial Motion using Dynamic Programming based Elastic Model
A semi-automatic motion-tracking method for local myocardial tissue on M-mode echocardiograms is proposed in this paper. The proposed method is applicable to estimating myocardial performance in clinics. The M-mode echocardiogram is a type of echocardiogram used in clinics to measure diagnostic indexes. Such as the thickening and thinning of myocardial muscle layers. In order to measure such in...
متن کاملNumber 5
A semi-automatic motion-tracking method for local myocardial tissue on M-mode echocardiograms is proposed in this paper. The proposed method is applicable to estimating myocardial performance in clinics. The M-mode echocardiogram is a type of echocardiogram used in clinics to measure diagnostic indexes. Such as the thickening and thinning of myocardial muscle layers. In order to measure such in...
متن کاملMeasurement of Left Ventricular Myocardium Wall Instantaneous Motions with Echocardiographic Sequence Images
Background & Aims: One of the important aims of quantitative cardiac image processing is the clarification of myocardial motions in order to derive biomechanical behavior of the heart in the disease condition. In this study we presented a computerized analysis method for detecting the instantaneous myocardial changes by using 2D echocardiography images. Methods: The analysis was performed on th...
متن کاملA quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates
Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...
متن کاملAutomatic detection of liver tumor motion by fluoroscopy images
Background: A method to track liver tumor motion signals from fluoroscopic images without any implanted gold fiducial markers was proposed in this study to overcome the adverse effects on precise tumor irradiation caused by respiratory movement. Materials and Methods: The method was based on the following idea: (i) Before treatment, a series of fluoroscopic images corresponding to different bre...
متن کامل