Interobserver Variability in Interpretation of Planar and SPECT Tc-99m-DMSA Renal Scintigraphy in Children

نویسندگان

  • Nermina Beslic
  • Renata Milardovic
  • Amera Sadija
  • Lejla Dzananovic
  • Semra Cavaljuga
چکیده

OBJECTIVE This study objective was to evaluate interobserver agreement between individual pairs of three nuclear medicine physicians in interpretation of renal cortical scintigraphy in children with respect to the mode of acquisition (planar vs. SPECT), diagnoses and kidney site (left vs. right). MATERIALS AND METHODS Thirty children were imaged in planar and SPECT mode per protocol upon the injection of Tc-99m DMSA dose adjusted to their body weight. Patients were classified according to diagnoses into four groups. Three nuclear medicine physicians interpreted the findings blindly and independently. Renal defects were interpreted as focal and diffuse, per three renal segments. For the raters we calculated simple percentage agreement, the Cohen kappa statistic with 95% confidence intervals, and the overall kappa defining the levels of reliability as almost perfect or perfect, substantial, moderate, fair and slight agreement. RESULTS Interobserver agreement in planar interpretation was 77,2% (kappa=0.59; 95% confidence interval, 0.41 to 0.75) and SPECT 72,9% (kappa= 0,57; 95% confidence interval, 0,41 to 0,72). In planar interpretation, all individual pairs had moderate agreements except one that had a substantial agreement. In SPECT, all the pairs had moderate agreements except one that had an almost perfect agreement. Overall agreement per kidney site was on planar 73,4% for the left (kappa=0,54, moderate agreement), and 81,1% for the right kidney (kappa 0,63, substantial agreement). On SPECT, there was 72,2% agreement for the left (kappa=0,59, mode rate agreement), and 73,7% for the right kidney (kappa=0,54, moderate agreement). Overall agreement per diagnoses ranged from 70-88,9% on planar (kappa= -0,04 to 0,79), and 50-100% on SPECT (kappa=-0,02-1,000) indicating agreements from slight to substantial. DISCUSSION Our results suggest acceptable levels of interobserver agreement in all individual pairs of raters with respect to the mode of acquisition (planar vs. SPECT), diagnoses and kidney site (left vs. right). For the mode of acquisition, we would recommend hybrid imaging SPECT/CT method to be used whenever possible in the detection of renal cortical defects on Tc-99m-DMSA scintigraphy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The comparison between ultrasonography and 99mTc-DMSA renal scan in estimation of kidney size

Introduction: Renal length measurement is an important diagnostic clue in several urinary tract abnormalities. Although ultra sonography is the most frequent used modality for renal size estimation, renal diameter assessment by 99mTc-DMSA scintigraphy is of great value. By now, pointing to the renal size in the 99mTc-DMSA scintigraphy report has not been recommended by gui...

متن کامل

Assessment of the maximum uptake time of 99mTc-DMSA in renal scintigraphy in rat

Introduction:The optimal imaging time of a radionuclide scintigraphy is the time at which the organ of interest has the maximum uptake of the injected radionuclide. This study was performed to investigate the maximum uptake time of 99mTc-DMSA in rat renal scan. Methods: Renal scintigraphy was performed with 3 mCi of 99mTc-DMSA. Planar ima...

متن کامل

Diagnostic dilemma of ectopic pelvic kidney in planar skeletal and renal cortical scintigraphy resolved by SPECT/CT

We present a 55-year old male patient who was subjected to whole body skeletal scintigraphy for metastatic work up of urinary bladder cancer. Whole body 99mTc-methylene diphosphonate (MDP) skeletal scintigraphy was performed. That revealed no skeletal metastasis in the entire body skeleton and normally visualized left kidney with empty right renal fossa. Additionally tracer activity ...

متن کامل

Inter- and intraobserver variability of (99m)Tc-DMSA renal scintigraphy: impact of oblique views.

UNLABELLED (99m)Tc-Dimercaptosuccinic acid (DMSA) scintigraphy is a frequently used diagnostic test to assess the presence and severity of cortical damage. The aim of this study is to investigate the variability in the interpretation of (99m)Tc-DMSA scans, evaluate the usefulness of oblique images, and assess their impact on scan interpretation. METHODS Two experienced nuclear medicine physic...

متن کامل

Hepatobiliary excretion of 99mTc-EC: A potential source of mistake in the interpretation of renal scintigraphy

A 10-year-old boy with a history of bloody discoloration of urine following recent appendectomy was referred to our department for urinary leakage/fistula evaluation. A renal Technetium-99m-L,L-ethylenedicysteine (99mTc-EC) scintigraphy was performed. After injection of radiotracer, a focus of activity appeared in the supralateral part of the right kidney which was confirmed as accum...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 25  شماره 

صفحات  -

تاریخ انتشار 2017