BACKGROUND Early identification of failing free flaps may allow for potential intervention and flap salvage. The predictive ability of flap temperature monitoring has been previously questioned. The present study investigated the ability of an infrared surface temperature monitoring device to detect trends in flap temperature and correlation with anastomotic thrombosis and flap failure. METHODS Postoperative measurement of surface temperature was obtained in 47 microvascular free flaps. Differences in temperature between survival and failure groups were evaluated for statistical significance using Student's t test (P<0.05). In addition, a single variable analysis was performed on 30 different flap characteristics to evaluate their prediction of flap failure. RESULTS In total, eight flaps failed. Five of these were re-explored, of which one was salvaged. The three other flaps died a progressive death secondary to presumed thrombosis of the microcirculation despite adequate Doppler signals. Temperatures of the flap failure group during the last 24 h yielded a mean difference of 2 degrees C (3.56 degrees F) compared with surviving flaps (P<0.05). The temperature of the failing flaps began to decline at the eighth postoperative hour. Single variable analysis identified prior radiation to be a predictor of flap failure. CONCLUSIONS A surface temperature measurement device provides reproducible digital readings without physical contact with the flap. Technical difficulties encountered in previous research with implantable or surface contact temperature probes are obviated with this noncontact technique. Flap temperature monitoring revealed a trend in temperature that correlates with anastomotic thrombosis and eventual flap failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Method of Noninvasive Monitoring of Free Flaps With Near-Infrared Spectroscopy

Objective: Thrombosis of a site of anastomosis in microsurgical free tissue transfer can result in tissue necrosis. To salvage potentially failing free flap, various methods of monitoring the viability of tissue have been described. We report a novel method of monitoring free flaps using near-infrared spectroscopy. Methods: After microsurgical operation, we monitored the regional oxygen saturat...

متن کامل

Numerical Prediction of Temperature Distribution in Transient RTM Process

Resin Transfer Molding (RTM) is a composite manufacturing process. A preformed fiber is placed in a closed mold and a viscous resin is injected into the mold. In this paper, a model is developed to predict the flow pattern, extent of reaction and temperature change during filling and curing in a thin rectangular mold. A numerical simulation is presented to predict the free surface and...

متن کامل

Effect of Dexamethasone Before Induction of Anesthesia On Postoperative Shivering

Abstract Shivering after surgery is common and followed by many problems. Therefore prevention of shivering is important specially in elderly and Ischemic Heart Disease patients. The etiology of shivering is unknown, although is thought intraoperative hypothermia is a major causative factor. Another possible etiology is fever and chills secondary to activation of the inflammatory responses and...

متن کامل

Comparison of Some Split-window Algorithms to Estimate Land Surface Temperature from AVHRR Data in Southeastern Tehran,

Land surface temperature (LST) is a significant parameter for many applications. Many studies have proposedvarious algorithms, such as the split-window method, for retrieving surface temperatures from two spectrallyadjacent thermal infrared bands of satellite data. Each algorithm is developed for a limited study area andapplication. In this paper, as part of developing an optimal split-window m...

متن کامل

Comparison of Variations of Water Stress Index of Chika Bean Plant under Surface Irrigation and Drip Tape Irrigation using Infrared Thermometer

The Plant Water Resistance Index (CWSI) is a tool that can be used for the rapid monitoring of plant water status, which is a key requirement for the accurate product irrigation management.The purpose of this study was to calculate the CWSI index for bean hares in the Khorramabad region for two methods of surface irrigation and drip tape ‎irrigation. For this purpose, a design was implemented i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Canadian journal of plastic surgery = Journal canadien de chirurgie plastique

دوره 17 3  شماره 

صفحات  -

تاریخ انتشار 2009