Optimization of coronary optical coherence tomography imaging using the attenuation-compensated technique: a validation study.

نویسندگان

  • Jing Chun Teo
  • Nicolas Foin
  • Fumiyuki Otsuka
  • Heerajnarain Bulluck
  • Jiang Ming Fam
  • Philip Wong
  • Fatt Hoe Low
  • Hwa Liang Leo
  • Jean-Martial Mari
  • Michael Joner
  • Michael J A Girard
  • Renu Virmani
چکیده

Aim To optimize conventional coronary optical coherence tomography (OCT) images using the attenuation-compensated technique to improve identification of plaques and the external elastic lamina (EEL) contour. Methods and Results The attenuation-compensated technique was optimized via manipulating contrast exponent C, and compression exponent N, to achieve an optimal contrast and signal-to-noise ratio (SNR). This was applied to 60 human coronary lesions (38 native and 22 stented) ex vivo conventional coronary OCT images acquired from heart autopsies of 10 patients and matching histology was available as reference. Three independent reviewers assessed the conventional and attenuation-compensated OCT images blindly for plaque characteristics and EEL detection. Conventional OCT and compensated OCT assessment were compared against histology. Using an optimized algorithm, the attenuation-compensated OCT images had a 2-fold improvement in contrast between different tissues in both stented and non-stented epicardial coronaries (P < 0.05). Overall sensitivity and specificity for plaque classification increased from 84 to 89% and from 92 to 94%, respectively, with substantial agreement among the three reviewers (Fleiss' Kappa k, 0.72 and 0.71, respectively). Furthermore, operators were 2.5 times more likely to identify the EEL contour in the attenuation-compensated OCT images (k = 0.72) than in the conventional OCT images (k = 0.36). Conclusion The attenuation-compensated technique can be retrospectively applied to conventional OCT images and improves the detection of plaque characteristics and the EEL contour. This approach could complement conventional OCT imaging in the evaluation of plaque characteristics and quantify plaque burden in the clinical setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Experimental Visualization of Labyrinthine Structure with Optical Coherence Tomography

Introduction:Visualization of inner ear structures is a valuable strategy for researchers and clinicians working on hearing pathologies. Optical coherence tomography (OCT) is a high-resolution imaging technology which may be used for the visualization of tissues. In this experimental study we aimed to evaluate inner ear anatomy in well-prepared human labyrinthine bones.Materials and Methods:Thr...

متن کامل

Comparison of Choroidal Thickness in Psoriasis and Control Groups Using Optical Coherence Tomography

Background and Objective: One of the most common extracutaneous complications in psoriasis patients is ocular complications, which is controversial concerning its effect on choroidal thickness. This study aimed to compare the psoriasis patients with healthy individuals in terms of the thickness of the choroidal layer using the optical coherence tomography technique. Materials and Methods: In t...

متن کامل

The Application of Multi-Layer Artificial Neural Networks in Speckle Reduction (Methodology)

Optical Coherence Tomography (OCT) uses the spatial and temporal coherence properties of optical waves backscattered from a tissue sample to form an image. An inherent characteristic of coherent imaging is the presence of speckle noise. In this study we use a new ensemble framework which is a combination of several Multi-Layer Perceptron (MLP) neural networks to denoise OCT images. The noise is...

متن کامل

Noise-compensated homotopic non-local regularized reconstruction for rapid retinal optical coherence tomography image acquisitions

BACKGROUND Optical coherence tomography (OCT) is a minimally invasive imaging technique, which utilizes the spatial and temporal coherence properties of optical waves backscattered from biological material. Recent advances in tunable lasers and infrared camera technologies have enabled an increase in the OCT imaging speed by a factor of more than 100, which is important for retinal imaging wher...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal cardiovascular Imaging

دوره 18 8  شماره 

صفحات  -

تاریخ انتشار 2017