Biofouling-Resistant Impedimetric Sensor for Array High-Resolution Extracellular Potassium Monitoring in the Brain
نویسندگان
چکیده
Extracellular potassium concentration, [K⁺]o, plays a fundamental role in the physiological functions of the brain. Studies investigating changes in [K⁺]o have predominantly relied upon glass capillary electrodes with K⁺-sensitive solution gradients for their measurements. However, such electrodes are unsuitable for taking spatio-temporal measurements and are limited by the surface area of their tips. We illustrate seizures invoked chemically and in optogenetically modified mice using blue light exposure while impedimetrically measuring the response. A sharp decrease of 1-2 mM in [K⁺]o before each spike has shown new physiological events not witnessed previously when measuring extracellular potassium concentrations during seizures in mice. We propose a novel approach that uses multichannel monolayer coated gold microelectrodes for in vivo spatio-temporal measurements of [K⁺]o in a mouse brain as an improvement to the conventional glass capillary electrode.
منابع مشابه
Oil Quality Monitoring in Gasoline Spark Ignition Engine Using Oil Dielectric Measurement
Oil analysis is one of the main methods for monitoring the status of internal combustion engines and oils to ensure the lubricant's protective performance and engine health. This paper investigate oil condition monitoring in gasoline engine using oil dielectric coefficient measurement. At first capacitive sensor pectinate type is designed and manufactured that engine oil can pass through the se...
متن کاملFunctionalized nano interdigitated electrodes arrays on polymer with integrated microfluidics for direct bio-affinity sensing using impedimetric measurement
This paper presents a fully integrated nano interdigitated electrodes array (nIDA) and microfluidic system on polymer substrate. It can be sed as a miniaturized, sensitive, and easy-to-use impedimetric sensor for genomics, proteomics, and cellular analysis. The benefits gained from nanoscale IDA is very high sensitivity for monitoring protein binding behavior. With the intention of integrating ...
متن کاملSpatial detection of ferromagnetic wires using GMR sensor and based on shape induced anisotropy
The purpose of this paper is to introduce a new technique for row spacing measurement in a wire array using giant magnetoresistive (GMR) sensor. The self-rectifying property of the GMR-based probes leads to accurately detection of the magnetic field fluctuations caused by surface-breaking cracks in conductive materials, shape-induced magnetic anisotropy, etc. The ability to manufacture probes h...
متن کاملDesign and Simulation of a Fluidic Micro-Bio-Sensor Based on Resonator Array
In this paper, a fluidic biosensor with possibility to fabricate by Micro-Electro-Mechanical Systems (MEMS) technology is proposed for biomedical mass detection and lab-on-chip applications. This is designed by electromechanical coupling of harmonic micromechanical resonators with harmonic springers as a mechanical resonator array. It can disperse mechanical wave along the array by electrostati...
متن کاملChemistry integrated circuit: chemical system on a complementary metal oxide semiconductor integrated circuit.
By integrating chemical reactions on a large-scale integration (LSI) chip, new types of device can be created. For biomedical applications, monolithically integrated sensor arrays for potentiometric, amperometric and impedimetric sensing of biomolecules have been developed. The potentiometric sensor array detects pH and redox reaction as a statistical distribution of fluctuations in time and sp...
متن کامل