Endothelial lamellar keratoplasty using an artificial anterior chamber and a microkeratome.
نویسندگان
چکیده
OBJECTIVE To compare postoperative astigmatic change and graft stability using 2 different donor button diameters in endothelial lamellar keratoplasty to treat corneal endothelial failure. METHODS A 200- micro m-thick corneal flap keratectomy was performed in human donor corneoscleral rims (n = 20; 10 donors and 10 recipients) using an artificial anterior chamber and a manual microkeratome (ALTK System; Moria USA, Doylestown, Pa). After flap reflection, stromal bed trephination was performed to obtain a disc consisting of posterior stroma, Descemet membrane, and endothelium. Host beds of 7.0 mm and 7.25-mm (n = 5) or 7.50-mm (n = 5) donor buttons were obtained using a freehand trephine. The graft was secured with 8 interrupted sutures (10-0 nylon) in the stromal bed. The flap was sutured with 3 interrupted sutures. Transplanted corneas were submitted to increasing intrachamber pressures to detect graft stability, and preoperative and postoperative videokeratographic data were recorded to assess astigmatic change. RESULTS The mean (SD) postoperative astigmatic change was 1.14 (3.17) diopters (D) in the 7.25-mm donor button group and 2.27 (1.77) D in the 7.50-mm donor button group (P =.69). Mean (SD) resisted pressures of 75.4 (44.81) mm Hg and 100.4 (46.86) mm Hg were observed in the 7.25-mm and 7.50-mm groups, respectively (P =.54). CONCLUSION Both donor button sizes exhibited similar graft stability and astigmatic postoperative change in this experimental model. CLINICAL RELEVANCE As endothelial lamellar keratoplasty becomes further developed as a clinical alternative to penetrating keratoplasty, this laboratory model system should be useful in evaluating different mechanical factors that contribute to graft success.
منابع مشابه
Microkeratome versus femtosecond laser predissection of corneal grafts for anterior and posterior lamellar keratoplasty.
PURPOSE To compare 2 different techniques for predissection of human anterior and posterior lamellar corneal grafts for eye bank storage. METHODS A mechanical microkeratome (group 1, N = 5) and a femtosecond laser (group 2, N = 5) were used to dissect intended 350-microm-deep lamellar planes in deepithelialized donor corneas mounted on an artificial anterior chamber. These corneas were replac...
متن کاملA new surgical technique of microkeratome-assisted deep lamellar keratoplasty with a hinged flap.
We describe a new surgical technique of microkeratome-assisted deep lamellar keratoplasty for treating patients with corneal stromal disease and normal endothelium. A microkeratome is used to create a hinged anterior stromal flap in the host cornea, and the diseased stroma is resected or ablated. A complementary donor stromal button, prepared using a microkeratome and an artificial anterior cha...
متن کاملEccentric lamellar keratolimbal grafts harvested with a manually guided microkeratome. Technical report.
BACKGROUND To perform lamellar keratolimbal allograft transplantation in a one-step procedure with a single graft, we investigated the feasibility of harvesting eccentric lamellar keratolimbal grafts from conventionally processed corneoscleral buttons using a manually guided microkeratome in conjunction with an artificial anterior chamber system. METHODS We used the Moria LSK-One microkeratom...
متن کاملUse of a Disposable Artificial Anterior Chamber for Trans-Epithelial Trephination and Endothelial Keratoplasty
The Barron artificial anterior chamber (Katena, Denville, NJ) is an innovative development in corneal transplant and lamellar surgery. The chamber is a specialized device that allows a donor corneoscleral cap of tissue to be anatomically positioned ‘‘epithelial side up.’’ The chamber is used to mount the donor tissue and maintain adequate pressure while lamellar dissection or full thickness tre...
متن کاملA Method to Prepare a Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) Graft Using Donor Corneas With Narrow Scleral Rims
Donor corneas with narrow scleral rims are often disqualified for Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK), mainly because of fluid leak and low pressure when they are mounted onto an artificial anterior chamber (AAC). This report describes a novel method to tight-lock a donor cornea with a narrow scleral rim so that microkeratome cutting is possible, allowing a DSAEK pro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of ophthalmology
دوره 121 4 شماره
صفحات -
تاریخ انتشار 2003