Feasibility of cognitive sparing approaches in children with intracranial tumors requiring partial brain radiotherapy: A dosimetric study using tomotherapy

نویسندگان

  • James C Marsh
  • Rohit Godbole
  • Aidnag Diaz
  • Arnold Herskovic
  • Julius Turian
چکیده

Background : To assess feasibility of sparing the neural stem cell compartment (NSC), hippocampus, and limbic circuit during partial brain radiotherapy (PBRT) for pediatric intracranial tumors. Methods : Treatment plans were generated for the following pediatric intracranial tumors: low and high grade gliomas, low grade brainstem glioma, optic nerve glioma, hypothalamic glioma, localized ependymoma, skull base sarcoma, central nervous system (CNS) germinoma (involved field radiotherapy [IFRT] and whole ventricular radiotherapy [WVRT] ), and craniopharyngioma. For each pathology, standard intensity-modulated radiotherapy (IMRT) plans were generated using helical tomotherapy, as well as IMRT plans which spared limbic circuit, hippocampus, and NSC. Biologically equivalent dose for late effects (BEDlate effects) was generated for limbic circuit, hippocampus, and NSC. Percent reduction in mean, maximum, and minimum physical dose and BED was calculated between plans. Results : We reduced mean physical dose and BEDlate effects to these critical structures by 44% and 47.9% respectively (range 5.4-78.8% and 7-80.3%). Greatest benefits in relative dose reduction were seen in high grade hemispheric glioma cases; least relative dose reduction was seen in WVRT cases. Dosimetric coverage of treatment target (PTV) was equivalent in all cases as assessed by D95 and V100 metrics. Integral dose to uninvolved brain was reduced by mean of 7.6% (range -19.3% to +0.3%) in sparing plans. Discussion and Conclusions : It is possible to spare limbic circuit, NSC, and hippocampus during PBRT for primary pediatric intracranial tumors using helical tomotherapy. This approach reduces integral dose delivered to uninvolved normal brain and may reduce late cognitive sequelae of cranial radiotherapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Evaluation of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy, and Helical Tomotherapy for Hippocampal-Avoidance Whole Brain Radiotherapy

BACKGROUND Whole brain radiotherapy (WBRT) is a vital tool in radiation oncology and beyond, but it can result in adverse health effects such as neurocognitive decline. Hippocampal Avoidance WBRT (HA-WBRT) is a strategy that aims to mitigate the neuro-cognitive side effects of whole brain radiotherapy treatment by sparing the hippocampi while delivering the prescribed dose to the rest of the br...

متن کامل

Dosimetric Study and Neurocognitive Function of Hippocampal-Sparing Whole-Brain Radiotherapy

Objective: To investigate the feasibility of hippocampal-sparing whole-brain radiotherapy and reduction in neurocognitive function impairment after radiotherapy. Methods: Forty-three patients with brain metastases were selected. Whole-brain radiotherapy was performed in 22 patients, with 3-dimensional conformal radiotherapy in parallel opposed fields. Twenty-one patients had significant differe...

متن کامل

Computerized Addenbrooke’s Cognitive Examination for Neurocognitive Monitoring of Children with Benign and Malignant Brain Cerebellar Tumor

Background: Brain tumors in the cerebellum site, especially in the cranial nuclei, are most commonly associated with cognitive impairment in children, but the differences in dimensions of cognitive impairments in pediatric benign and malignant tumors are rarely studied. Meanwhile, cognitive impairments in this area are required to be widely studied. This study aimed at using Computerized Addenb...

متن کامل

Helical tomotherapy simultaneous integrated boost provides a dosimetric advantage in the treatment of primary intracranial tumors.

OBJECTIVE The research quantitatively evaluates the dosimetric advantage of a helical tomotherapy (HT) intensity-modulated radiation therapy simultaneous integrated boost (SIB) compared to a conventional HT sequential (SEQ) boost for primary intracranial tumors. METHODS Hypothetical lesions (planning target volumes or PTVs) were contoured within computed tomography scans from normal controls....

متن کامل

High-dose pre-operative helical tomotherapy (54 Gy) for retroperitoneal liposarcoma

PURPOSE To evaluate the feasibility of pre-operative radiotherapy (54 Gy) with Helical Tomotherapy (HT) followed by surgery. METHODS AND MATERIALS Ten patients with non-metastatic resectable retroperitoneal liposarcomas were treated by pre-operative tomotherapy (54 Gy) and surgery. Clinical and biological toxicities were evaluated on the CTCAEV3.0 scale. For nine patients, delivered tomothera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012