Enhanced indirect fluorescence detection of p-nitrophenol, 2,4-dinitrophenol and trinitrophenol by micellar electrokinetic capillary chromatography with in-column optical-fiber LED-induced fluorescence detection.
نویسندگان
چکیده
Enhanced indirect fluorescence detection with in-column optical-fiber LED-induced fluorescence (LED-IF) detection has been developed for the simultaneous separation and determination of p-nitrophenol, 2,4-dinitrophenol and trinitrophenol. The instrumental set-up is simple, cost-effective and the detection method is stable. Different experimental parameters have been studied. The optimum conditions were determined as: running buffer (pH 9.1) composed of 10 mM borate, 80 mM sodium dodecylsulfate and 0.18 µM fluorescein (as a background reagent); applied voltage of 15 kV; working temperature of 25.0 °C. The limits of detection (S/N = 3) were 11, 18 and 16 µM for p-nitrophenol, 2,4-dinitrophenol and trinitrophenol, respectively. The nitrophenols were completely separated in 13 min and the number of theoretical plates for p-nitrophenol, 2,4-dinitrophenol and trinitrophenol were 8.1 × 10(6), 6.5 × 10(6) and 8.4 × 10(6), respectively. The RSDs (n = 6) for the migration time and the peak area were better than 0.85 and 0.91%, respectively. Our proposed method possesses the advantages of rapidness and good separation efficiency.
منابع مشابه
Violet light emitting diode-induced fluorescence detection combined with on-line sample concentration techniques for use in capillary electrophoresis.
The first application of a violet light-emitting diode (LED) for fluorescence detection in capillary electrophoresis (CE) is described. The utility of violet LED (peak emission wavelength at 410 nm, approximately 2 mW) for fluorescence detection is demonstrated by examining reserpine and dopamine-labeled NDA (naphthalene-2,3-dicarboxaldehyde), respectively. The detection limit for reserpine was...
متن کاملOptimization of the separation and on-line sample concentration of phenethylamine designer drugs with capillary electrophoresis-fluorescence detection.
Five 2C-series of phenethylamine designer drugs, including 2,5-dimethoxy-4-ethylthio-phenethylamine (2C-T-2), 2,5-dimethoxy-4-(n)-propylthiophenethylamine (2C-T-7), 4-chloro-2,5-dimethoxyphenethylamine (2C-C), 4-bromo-2,5-dimethoxy-phenethylamine (2C-B), 2,5-dimethoxy-4-iodo-phenethylamine (2C-I), were synthesized and standard GC/MS and fluorescence spectra are reported for them. A mixture of t...
متن کاملMixed Micellar Electrokinetic Chromatographic Analysis of Colistin, Polypeptide Antibiotic, Using Laser-Induced Fluorescence Detection
The main goal of this work was to quantify the detection of colistin at low levels in urine samples through the practical application of mixed surfactant micellar electrokinetic chromatography-laser-induced fluorescence (MEKC-LIF) analysis method using its advantage of sensitivity and to examine direct injection of biological samples. Colistin (polymyxin E) has neither strong UV chromophore nor...
متن کاملDetermination of aminoglycoside antibiotics in pharmaceuticals by capillary zone electrophoresis with indirect UV detection coupled with micellar electrokinetic capillary chromatography.
Aminoglycoside antibiotics can be determined by capillary zone electrophoresis (CZE) with indirect UV detection in the anionic mode with a reversed electroosmotic flow (EOF) by addition of FC 135 to the background electrolyte. The effective mobilities of thirteen aminoglycoside antibiotics were determined as a function of pH. Applying CZE with indirect UV detection in the anionic mode and rever...
متن کاملMethanol plug assisted sweeping-micellar electrokinetic chromatography for the determination of dopamine in urine by violet light emitting diode-induced fluorescence detection.
The use and limitations of a methanol plug assisted sweeping-micellar electrokinetic chromatography (sweeping-MEKC) method is described. Using naphthalene-2,3-dicarboxaldehyde (NDA)-labeled dopamine as a model compound, this new method was also used in the determination of dopamine in actual urine samples. An inexpensive violet light emitting diode (LED) was used for the light source, because t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 27 9 شماره
صفحات -
تاریخ انتشار 2011