Can Pre-Retrieval Computed Tomography Predict the Difficult Removal of an Implementing an Inferior Vena Cava Filter?

نویسندگان

  • Shinho Hong
  • Keun-Myoung Park
  • Yong Sun Jeon
  • Soon Gu Cho
  • Kee Chun Hong
  • Woo Young Shin
  • Yun-Mee Choe
چکیده

PURPOSE Implementing an inferior vena cava (IVC) filter is a relatively safe procedure but potential negative long-term effects. The complications for filter retrieval have been noted. We examined filter characteristics on pre-retrieval computed tomography (CT) that were associated with complicated retrieval (CR) of IVC filters. MATERIALS AND METHODS A retrospective review of IVC filter retrievals between January 2008 and June 2014 was performed to identify patients who had undergone a pre-retrieval CT for IVC filter retrieval. CR was defined as the use of nonstandard techniques, procedural time over 30 min, filter fractures, filter tip incorporation into the IVC wall, and retrieval failure. Pre-retrieval CT images were evaluated for tilt angle in the mediolateral and anteroposterior directions, tip embedding into the IVC wall, degree of filter strut perforation, and distance of the filter tip from the nearest renal vein. RESULTS Of seventy-six patients, twenty-four patients (31.6%) with CRs and 56 patients (73.7%) with non-CR were evaluated for pre-retrieval CT. For IVC filter retrieval with a dwelling time of over 45 days, a tilt of over 15 degrees, the appearance of tip embedding and grade 2 perforation were associated with CR on multivariate analysis. However, for IVC filter retrievals with a dwelling time of less than 45 days, there were no factors associated with CR. CONCLUSION Pre-retrieval CTs may be more effective for IVC filters with a dwelling time of over 45 days. Therefore, a pre-retrieval CT may be helpful in predicting CR of IVC filters with long dwelling times.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful cases of difficult inferior vena cava filter retrieval with the use of biopsy forceps: Biopsy forceps technique

OBJECTIVES For treatment and prevention of deep vein thrombosis(DVT) and pulmonary embolism(PE), retrievable inferior vena cava(IVC) filters have commonly been used as an effective bridge to anticoagulation. However, we experienced unexpected difficulty in endovascular retrieval of some IVC filters. Most problems were due to endovascular treatment devices issues, filter intimal migration, filte...

متن کامل

Inferior vena cava filter penetration following Whipple surgical procedure causing ureteral injury.

We report a case of an indwelling inferior vena cava filter that penetrated the IVC wall after Whipple's pancreatico-duodenectomy procedure performed in a patient with ampullary carcinoma, resulting in right ureteral injury and obstruction with subsequent hydroureter and hydronephrosis. This was incidentally discovered on a computed tomography scan performed as routine follow up to evaluate the...

متن کامل

Late endovascular removal of Günther-Tulip inferior vena cava filter and stent reconstruction of chronic post-thrombotic iliocaval obstruction after 4753 days of filter dwell time: a case report with review of literature

Chronic post-thrombotic obstruction of the inferior vena cava (IVC) or iliocaval junction is an uncommon complication of long indwelling IVC filter. When such an obstruction is symptomatic, endovascular treatment options include stent placement with or without filter retrieval. Filter retrieval becomes increasingly difficult with longer dwell times. We present a case of symptomatic post-thrombo...

متن کامل

Pulmonary embolism averted: trapped thrombus in inferior vena cava filters.

A 55-year-old morbidly obese male (body mass index 54) underwent placement of a prophylactic inferior vena cava (IVC) filter before a laparoscopic sleeve gastrectomy. Preoperative lower extremity venous duplex examination was negative for deep vein thrombosis. He was discharged home on postoperative day 3 after the bariatric procedure and had an uneventful recovery. Approximately 7 weeks later,...

متن کامل

Successful removal of a Gunther tulip vena cava filter with wall-embedded hook and migration during a retrieval attempt

Retrieval of a Gunther tulip vena cava filter implanted in a patient with inferior vena cava and right common iliac vein thrombosis was attempted by the standard method. Because the filter was tilted, the hook became attached to the vena cava wall and could not be snared. During attempts at removal by an alternative method, the filter migrated toward the right atrium. However, it was finally su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 32  شماره 

صفحات  -

تاریخ انتشار 2016