Development of a test system to analyze different hip fracture osteosyntheses under simulated walking.
نویسندگان
چکیده
The mechanical complications of osteosyntheses after hip fractures are previously investigated by mostly static or dynamic uniaxial loading test systems. However, the physiologic loading of the hip joint during a normal gait is a multiplanar, dynamic movement. Therefore, we constructed a system to test osteosyntheses for hip fractures under physiologic multiplanar loading representative of normal gait. To evaluate the testing system, 12 femora pairs were tested under 25,000 cycles with two standard osteosyntheses (Proximal Femoral Nail Antirotation/Gamma3 Nail). For angular movement, the varus collapse to cut out (∝CO) (∝CO=4.8°±2.1° for blade and ∝CO=7.8°±3.8° for screw) was the dominant failure mode, and only slight rotational angle shifts (∝Rot) (∝Rot=1.7°±0.4° for blade and ∝Rot=2.4°±0.3° for screw) of the femoral head around the implant axis were observed. Angular displacements in varus direction and rotation were higher in specimens reinforced with screws. Hence, the cut out model and the migration directions showed a distinction between helical blade and hip screw. However, there were no significant differences between the different implants. The new setup is able to create clinical failures and allows to give evidence about the anchorage stability of different implant types under dynamic gait motion pattern.
منابع مشابه
Biomechanical analysis of different osteosyntheses and the combination with bone substitute in tibial head depression fractures
BACKGROUND Tibial head depression fractures demand a high level of fracture stabilization to prevent a secondary loss of reduction after surgery. Elderly individuals are at an increased risk of developing these fractures, and biomechanical investigations of the fractures are rare. Therefore, the aim of this study was to systematically analyze different types of osteosyntheses in combination wit...
متن کاملWalking ability and activity level after hip fracture in the elderly--a follow-up.
OBJECTIVE The purpose of this study was to investigate which variables can predict walking ability and activity level 1 year after hip fracture and to describe changes over time regarding functional capacity. SUBJECTS One hundred and fifty-seven patients (111 women, 46 men), mean age 80.9 (SD 9.5) years, operated on for hip fracture, and able to participate either fully or to some extent in p...
متن کاملMeasures of physical functioning after hip fracture: construct validity and responsiveness of performance-based and self-reported measures.
OBJECTIVES this study aimed to investigate the construct validity and responsiveness of performance-based and self-reported measures of strength, mobility and balance after hip fracture. DESIGN secondary analysis of clinical trial data. SUBJECTS a total of 148 older people undergoing hip fracture rehabilitation. METHODS correlation coefficients assessed construct validity. Internal respon...
متن کاملLag screws for hip fracture fixation: Evaluation of migration resistance under simulated walking.
Previous mechanical studies concerning cut-out of lag screws for pertrochanteric hip fractures have relied on static or dynamic uniaxial loading regimens to induce construct failure by varus collapse and superior cut-out. However, the hip is loaded in a multiplanar, dynamic manner during normal gait. We designed a hip implant performance simulator (HIPS) system to evaluate lag screw cut-out und...
متن کاملNew Insight on Deformation of Walnut/Ceramic Proppant Pack under Closure Stress in Hydraulic Fracture: Numerical Investigation
This study is an attempt to investigate the mechanical behavior of proppant packs deforming under compression loading. A generalized confined compression test (CCT) was simulated in the present study to investigate the deformation of walnut/ceramic proppants against compression. In this way, the CCT was simulated using ABAQUS explicit code. Unlike ordinary CCT, we obtained permeability of compr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedizinische Technik. Biomedical engineering
دوره 57 2 شماره
صفحات -
تاریخ انتشار 2012