Accuracy of Digital Breast Tomosynthesis for Depicting Breast Cancer Subgroups in a UK Retrospective Reading Study (TOMMY Trial).
نویسندگان
چکیده
PURPOSE To compare the diagnostic performance of two-dimensional (2D) mammography, 2D mammography plus digital breast tomosynthesis (DBT), and synthetic 2D mammography plus DBT in depicting malignant radiographic features. MATERIALS AND METHODS In this multicenter, multireader, retrospective reading study (the TOMMY trial), after written informed consent was obtained, 8869 women (age range, 29-85 years; mean, 56 years) were recruited from July 2011 to March 2013 in an ethically approved study. From these women, a reading dataset of 7060 cases was randomly allocated for independent blinded review of (a) 2D mammography images, (b) 2D mammography plus DBT images, and (c) synthetic 2D mammography plus DBT images. Reviewers had no access to results of previous examinations. Overall sensitivities and specificities were calculated for younger women and those with dense breasts. RESULTS Overall sensitivity was 87% for 2D mammography, 89% for 2D mammography plus DBT, and 88% for synthetic 2D mammography plus DBT. The addition of DBT was associated with a 34% increase in the odds of depicting cancer (odds ratio [OR] = 1.34, P = .06); however, this level did not achieve significance. For patients aged 50-59 years old, sensitivity was significantly higher (P = .01) for 2D mammography plus DBT than it was for 2D mammography. For those with breast density of 50% or more, sensitivity was 86% for 2D mammography compared with 93% for 2D mammography plus DBT (P = .03). Specificity was 57% for 2D mammography, 70% for 2D mammography plus DBT, and 72% for synthetic 2D mammography plusmDBT. Specificity was significantly higher than 2D mammography (P < .001in both cases) and was observed for all subgroups (P < .001 for all cases). CONCLUSION The addition of DBT increased the sensitivity of 2D mammography in patients with dense breasts and the specificity of 2D mammography for all subgroups. The use of synthetic 2D DBT demonstrated performance similar to that of standard 2D mammography with DBT. DBT is of potential benefit to screening programs, particularly in younger women with dense breasts. (©) RSNA, 2015.
منابع مشابه
Digital breast tomosynthesis (DBT): a review of the evidence for use as a screening tool.
Breast screening with full-field digital mammography (FFDM) fails to detect 15-30% of cancers. This figure is higher for women with dense breasts. A new tomographic technique in mammography has been developed--digital breast tomosynthesis (DBT)--which allows images to be viewed in sections through the breast and has the potential to improve cancer detection rates. Results from retrospective rea...
متن کاملThe TOMMY trial: a comparison of TOMosynthesis with digital MammographY in the UK NHS Breast Screening Programme--a multicentre retrospective reading study comparing the diagnostic performance of digital breast tomosynthesis and digital mammography with digital mammography alone.
BACKGROUND Digital breast tomosynthesis (DBT) is a three-dimensional mammography technique with the potential to improve accuracy by improving differentiation between malignant and non-malignant lesions. OBJECTIVES The objectives of the study were to compare the diagnostic accuracy of DBT in conjunction with two-dimensional (2D) mammography or synthetic 2D mammography, against standard 2D mam...
متن کاملUltra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU
Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...
متن کاملPublications for Petra Macaskill 2017
Houssami, N., Bernardi, D., Pellegrini, M., Valentini, M., Fanto, C., Ostillio, L., Tuttobene, P., Luparia, A., Macaskill, P. (2017). Breast cancer detection using single-reading of breast tomosynthesis (3D-mammography) compared to doublereading of 2D-mammography: Evidence from a populationbased trial. Cancer Epidemiology, 47, 94-99. [More...
متن کاملImproving Reading Time of Digital Breast Tomosynthesis with Concurrent Computer Aided Detection
PowerLook® Tomo Detection, a concurrent computer-aided detection (CAD) system for digital breast tomosynthesis (DBT) developed by iCAD, Inc., Nashua, NH, was tested to determine if the software can shorten the reading time of DBT without affecting radiologist interpretation or performance. The results of this study showed a 29.2% average reduction in reading time (up to 36.5% reduction) with th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 277 3 شماره
صفحات -
تاریخ انتشار 2015