Swallowing a Tiny Imaging Capsule Aids in Diagnosis of Obscure Gastrointestinal Bleeding

نویسنده

  • Ramona M. Lim
چکیده

Swallowing a Tiny Imaging Capsule Aids in Diagnosis of Obscure Gastrointestinal Bleeding The use of a small wireless capsule video device to detect bleeding in the small intestine is safe, well-tolerated, and more accurate than another common diagnostic approach according to a study presented at a meeting of the American College of Gastroenterology. “The investigation of obscure gastrointestinal bleeding is often difficult due to limitations of conventional endoscopic studies in the detection of disorders in the small intestine,” said Ramona M. Lim, M.D., of the University of Miami School of Medicine/Mount Sinai Medical Center in Miami, FL. Patients with obscure GI bleeding experience bleeding of unknown origin that persists or recurs after a negative initial endoscopy (colonoscopy and/or upper GI endoscopy). For some of these patients the bleeding may be caused by lesions in the small intestine that would not be detected with colonoscopy or upper GI endoscopy. In wireless capsule endoscopy, the patient swallows a tiny imaging capsule that incorporates a light source, video camera, battery, antenna and radio transmitter. Images of the intestinal tract are transmitted twice each second by radio frequency to an array of sensors worn around the patient’s abdomen and the signals are digitally recorded on a device that is later downloaded. The patient swallows the capsule in the morning and wears the recording device for 8-hours. The capsule is eliminated and discarded. A gastroenterologist reviews the images. Dr. Lim and her colleagues studied 20 patients with GI bleeding from an unidentified source. Researchers evaluated these patients using the wireless capsule technology, then followed up using a technique known as push enteroscopy. In push enteroscopy, a four-foot long tube outfitted with a small video camera is inserted down the esophagus, through the stomach and into the first third of the small intestine. The researchers found that wireless capsule endoscopy identified potential sources of bleeding in 70 percent of the patients, compared to 45 percent with push enteroscopy. While the Miami study revealed that this technology is more sensitive than push enteroscopy in detecting problems in the small intestine, it is not without drawbacks. With wireless capsule endoscopy a gastroenterologist cannot biopsy or treat pathologies in the small intestine. The use of this technology is not appropriate for patients with bowel obstructions. The M2A capsule is manufactured by Given Imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuing challenges in the diagnosis and management of obscure gastrointestinal bleeding.

The diagnosis and management of obscure gastrointestinal bleeding (OGIB) have changed dramatically since the introduction of video capsule endoscopy (VCE) followed by deep enteroscopy and other imaging technologies in the last decade. Significant advances have been made, yet there remains room for improvement in our diagnostic yield and treatment capabilities for recurrent OGIB. In this review,...

متن کامل

Virtual chromoendoscopy improves the diagnostic yield of small bowel capsule endoscopy in obscure gastrointestinal bleeding.

BACKGROUND Small bowel capsule endoscopy represents the initial investigation for obscure gastrointestinal bleeding. Flexible spectral imaging colour enhancement (FICE) is a virtual chromoendoscopy technique designed to enhance mucosal lesions, available in different settings according to light wavelength-- FICE1, 2 and 3. AIMS To compare the diagnostic yield of FICE1 and white light during c...

متن کامل

A leiomyosarcoma of the small bowels causing obscure gastrointestinal bleeding diagnosed by capsule endoscopy.

An 80-year-old woman presented with recurrent occult gastrointestinal bleeding requiring blood transfusions. She underwent endoscopy and colonoscopy that failed to identify the cause of bleeding. An enteroscopy revealed duodenal arteriovenous malformation that was cauterized. However, anemia and occult gastrointestinal bleeding recurred. A repeat enteroscopy was negative. A wireless capsule end...

متن کامل

Diagnosis of Obscure Gastrointestinal Bleeding

Obscure gastrointestinal bleeding (OGIB) is defined as gastrointestinal bleeding from a source that cannot be identified on upper or lower gastrointestinal endoscopy. OGIB is considered an important indication for capsule endoscopy (CE). CE is particularly useful for the detection of vascular and small ulcerative lesions, conditions frequently associated with OGIB, particularly in Western count...

متن کامل

Diagnostic yield of capsule endoscopy in a tertiary hospital in patients with obscure gastrointestinal bleeding.

BACKGROUND AND AIMS Capsule endoscopy is applicable to several clinical conditions, but obscure gastrointestinal bleeding remains the main indication. This study aims at determining the diagnostic yield of capsule endoscopy for obscure gastrointestinal bleeding using a structured terminology in a large cohort in an academic hospital. METHODS In this retrospective study, 592 capsule endoscopy ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004