Implant Surface Temperature Changes during Er:YAG Laser Irradiation with Different Cooling Systems

نویسندگان

  • Abbas Monzavi
  • Sima Shahabi
  • Reza Fekrazad
  • Roohollah Behruzi
  • Nasim Chiniforush
چکیده

OBJECTIVE Peri-implantitis is one of the most common reasons for implant failure. Decontamination of infected implant surfaces can be achieved effectively by laser irradiation; although the associated thermal rise may cause irreversible bone damage and lead to implant loss. Temperature increments of over 10ºC during laser application may suffice for irreversible bone damage. PURPOSE OF STUDY The purpose of this study was to evaluate the temperature increment of implant surface during Er:YAG laser irradiation with different cooling systems. MATERIALS AND METHODS Three implants were placed in a resected block of sheep mandible and irradiated with Er:YAG laser with 3 different cooling systems namely water and air spray, air spray alone and no water or air spray. Temperature changes of the implant surface were monitored during laser irradiation with a K-type thermocouple at the apical area of the fixture. RESULTS In all 3 groups, the maximum temperature rise was lower than 10°C. Temperature changes were significantly different with different cooling systems used (P<0.001). CONCLUSION Based on the results, no thermal damage was observed during implant surface decontamination by Er:YAG laser with and without refrigeration. Thus, Er:YAG laser irradiation can be a safe method for treatment of periimplantitis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of double acid-etched implants

PURPOSE One of the most frequent complications related to dental implants is peri-implantitis, and the characteristics of implant surfaces are closely related to the progression and resolution of inflammation. Therefore, a technical modality that can effectively detoxify the implant surface without modification to the surface is needed. The purpose of this study was to evaluate the effect of er...

متن کامل

Effects of Laser Treatment on Intracanal Dentine and Cementum at the Root Apex

Laser irradiation during root canal treatment is efficient but in order to prevent irreversible thermal damage to dentine, cementum and other periapical structures continuous water cooling is required. The aim of this study was to ultrastructurally analyze the surface of intracanal dentine and cementum at the root apex after Er:YAG laser irradiation with and without sterile saline solution irri...

متن کامل

Thermodynamic effects after Diode and Er:YAG laser irradiation of grade IV and V titanium implants placed in bone - an ex vivo study. Preliminary report.

Many inserted implants are affected by peri-implantitis. The aim of our study was to evaluate increases in implant temperature, depending on the diameter and chemical composition of implants. In particular we measured the time it takes for the temperature of an implant to rise by 10°C and evaluated laser power settings required to prevent thermal injury when an implant surface is decontaminated...

متن کامل

The effect of Er:YAG laser irradiation on the surface microstructure and roughness of hydroxyapatite-coated implant

PURPOSE The present study was performed to evaluate the effect of erbium:yttrium-aluminium-garnet (Er:YAG) laser irradiation on the change of hydroxyapatite (HA)-coated implant surface microstructure according to the laser energy and the application time. METHODS The implant surface was irradiated by Er:YAG laser under combination condition using the laser energy of 100 mJ/pulse, 140 mJ/pulse...

متن کامل

Effect of ER:YAG and diode laser irradiation on the root surface: morphological and thermal analysis.

BACKGROUND The aim of the present study was to compare the effects of Er:YAG and diode laser treatments of the root surface on intrapulpal temperature after scaling and root planing with hand instruments. METHODS Fifteen extracted single-rooted teeth were scaled and root planed with hand instruments. The teeth were divided into 3 groups of 5 each and irradiated on their buccal and lingual sur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2014