Automated Lung Tumor Detection and Quantification for Respiratory Gated PET/CT Images
نویسندگان
چکیده
Purpose: To develop and validate an automatic algorithm for the detection and functional assessment of lung tumors on three-dimensional respiratory gated PET/CT images. Method and Materials: First the algorithm will automatically segment lung regions in CT images, then identify and localize focal increases of activity in lung regions of PET images at each gated bin. Once the tumor voxels have been determined, an integration algorithm will include all the tumor counts collected at different bins within the respiratory cycle into one reference bin. Then the total activity (Bq), concentration (Bq/ml), functional volume (ml) and standard uptake values (SUV) are calculated for each tumor on PET images. Validation of the automatic algorithm was demonstrated by conducting experiments with the computerized 4D NCAT phantom and with a dynamic lung-chest phantom imaged using a GE PET/CT System at Baptist Hospital of Miami. Tumor variables to be controlled were: volume, total number of counts (activity), maximum and average number of counts. These values were the gold standard to which the results of the algorithm were compared. The tumor’s motion was also controlled with different respiratory periods and amplitudes. Results: Validation, feasibility and robustness of the algorithm were demonstrated. With the algorithm, the best compromise between short PET scan time and reduced image noise can be achieved, while quantification and clinical analysis become faster and more precise.
منابع مشابه
Automated classification of pulmonary nodules through a retrospective analysis of conventional CT and two-phase PET images in patients undergoing biopsy
Objective(s): Positron emission tomography/computed tomography (PET/CT) examination is commonly used for the evaluation of pulmonary nodules since it provides both anatomical and functional information. However, given the dependence of this evaluation on physician’s subjective judgment, the results could be variable. The purpose of this study was to develop an automated scheme for the classific...
متن کاملFeasibility of Systematic Respiratory-Gated Acquisition in Unselected Patients Referred for 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography
Objective Respiratory motion in 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) induces blurred images, leading to errors in location and quantification for lung and abdominal lesions. Various methods have been developed to correct for these artifacts, and most of current PET/CT scanners are equipped with a respiratory gating system. However, they are not ro...
متن کاملPET/CT in non-small-cell lung cancer: value of respiratory-gated PET.
The use of PET in the staging of patients with NSCLC is cost-effective, mainly due to a reduction in the number of futile operations. The addition of SUVmax to pathologic tumor size identifies a subgroup of patients at highest risk for death as a result of recurrent disease after resection. Tumor staging is more accurate with PET-CT than with CT alone or with PET alone. The greatest source of e...
متن کاملEvaluation of methods of co-segmentation on PET/CT images of lung tumor: simulation study
Introduction: Lung cancer is one of the most common causes of cancer-related deaths worldwide. Nowadays PET/CT plays an essential role in radiotherapy planning specially for lung tumors as it provides anatomical and functional information simultaneously that is effective in accurate tumor delineation. The optimal segmentation method has not been introduced yet, however several ...
متن کاملImpact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer
AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...
متن کامل