چکیده

UNLABELLED The radioactivity in the organs adjacent to the heart causes interference with the quantitative assessment of myocardial uptake of tracer on scintigraphy. In order to investigate how much the functions of these organs affect myocardial uptake seen in imaging, we compared the myocardial uptake measured by means of a gamma camera with the actual activity in the excised organs. METHODS Thirty-three rats were imaged at 5, 10, 15, 30, 45, 60, 90 and 120 min after the administration of 99mTc-tetrofosmin, and % injected dose per pixel (%ID/pixel) for each organ was assessed on planar images (PI measurement). Percent injected dose per gram of tissue (%ID/g) in the heart as well as lungs, liver, gastrointestines and blood was measured by means of a well scintillation counter (WC measurement). Comparison between PI and WC measurements was performed with % uptake, the PI-to-WC ratio and heart-to-organ ratios. RESULTS Our WC measurement showed an increase in cardiac uptake until 30 min (1.67 +/- 0.31%) postinjection and subsequent gradual decrease, whereas PI measurement showed maximum activity of 1.81 +/- 0.52% at 15 min postinjection. There was a prominent difference between the two measurements, particularly at 10 min, with a PI/WC ratio of about 1.6 times. Our WC measurement showed maximum pulmonary uptake at 15 min (0.87 +/- 0.31%) and a gradual decrease over 15 min, whereas PI measurement showed maximum uptake at 10 min (1.14 +/- 0.38%). There was hardly any variation in activity observed later than at 10 min. Our WC measurement showed hardly any variance in hepatic activity from 5 min (0.77 +/- 0.19%) to 30 min (0.69 +/- 0.27%) with a subsequent gradual decrease. The percent uptake in PI measurement was generally greater than that in WC measurement, and high values were found at 10 min and 15 min with PI/WC ratios of about 3.3 times and 2.3 times, respectively. CONCLUSION Percent uptakes in PI measurement were greater than those in WC measurement. The difference between the two measurements was prominent in the early phases. The cardiac uptake in PI measurement was significantly greater than that in WC measurement at 10 min. It was considered that this discrepancy between the two measurements was caused by the Compton scatter from the organs adjacent to the heart.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of ِdiagnostic role of 99mTc-Tetrofosmin scintigraphy in cold thyroid nodules [Persian]

Introduction: Various radiopharmaceuticals, including 67Ga, 201Tl, and 99mTc-sestamibi have been used to differentiate benign from malignant thyroid nodules. 99mTc-Tetrofosmin, a lipophilic cationic radiotracer, and 99mTc-sestamibi have also been reported to accumulate in thyroid tumors. In this study, we evaluated the role of 99mTc-Tetrofosmin in the differentiation of malignant from ben...

متن کامل

99mTc-Tetrofosmin in Rats

99mTc-[bis (dimethoxypropylphosphinoethyl)-ethoxyethylamine (PNP5)]-[bis (N-ethoxyethyl)-dithiocarbamato (DBODC)] nitride (N-PNP5-DBODC or N-DBODC5) is a new monocationic myocardial perfusion tracer. We sought to compare the myocardial uptake and clearance kinetics and organ biodistribution of 99mTc-N-DBODC5 with 99mTc-sestamibi and 99mTc-tetrofosmin. Methods: Seventy-five anesthetized Sprague–...

متن کامل

Estimating the Absorbed Dose of Organs in Pediatric Imaging of 99mTc-DTPA Radiopharmaceutical using MIRDOSE Software

Introduction: In this study, organ radiation doses were calculated for the renal agent 99mTc-DTPA in children. Bio-kinetic energy of 99mTc-DTPA was evaluated by scintigraphy and estimates for absorbed radiation dose were provided using standard medical internal radiation dosimetry (MIRD) techniques.Material and Methods: In this applied research, fourteen children patients (6 males and 8 females...

متن کامل

Evaluation of Simultaneous Dual-radioisotope SPECT Imaging Using 18F-fluorodeoxyglucose and 99mTc-tetrofosmin

Objective(s): Use of a positron emission tomography (PET)/single-photonemission computed tomography (SPECT) system facilitates the simultaneousacquisition of images with fluorine-18 fluorodeoxyglucose (18F-FDG) andtechnetium (99mTc)-tetrofosmin. However, 18F has a short half-life, and 511keV Compton-scattered photons are detected in the 99mTc energy window.Therefore, in this study, we aimed to ...

متن کامل

The value of Tc-99m-tetrofosmin scintigraphy in the assessment of P-glycoprotein in patients with malignant bone and soft-tissue tumors.

UNLABELLED P-glycoprotein (Pgp) overexpression has been shown to be correlated with resistance to chemotherapy in patients with malignant bone and soft-tissue tumors. The aim of our study was to investigate the role of 99mTc-tetrofosmin as a functional imaging agent reflecting Pgp expression in these tumors. METHODS Twenty eight patients with various malignant bone and soft-tissue tumors were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 15 1  شماره 

صفحات  -

تاریخ انتشار 2001