Development of an Integrated Reporting System for Verifying Hemolysis, Icterus, and Lipemia in Clinical Chemistry Results
نویسندگان
چکیده
BACKGROUND Hemolysis, icterus, and lipemia (HIL) cause preanalytical interference and vary unpredictably with different analytical equipments and measurement methods. We developed an integrated reporting system for verifying HIL status in order to identify the extent of interference by HIL on clinical chemistry results. METHODS HIL interference data from 30 chemical analytes were provided by the manufacturers and were used to generate a table of clinically relevant interference values that indicated the extent of bias at specific index values (alert index values). The HIL results generated by the Vista 1500 system (Siemens Healthcare Diagnostics, USA), Advia 2400 system (Siemens Healthcare Diagnostics), and Modular DPE system (Roche Diagnostics, Switzerland) were analyzed and displayed on physicians' personal computers. RESULTS Analytes 11 and 29 among the 30 chemical analytes were affected by interference due to hemolysis, when measured using the Vista and Modular systems, respectively. The hemolysis alert indices for the Vista and Modular systems were 0.1-25.8% and 0.1-64.7%, respectively. The alert indices for icterus and lipemia were <1.4% and 0.7% in the Vista system and 0.7% and 1.0% in the Modular system, respectively. CONCLUSIONS The HIL alert index values for chemical analytes varied depending on the chemistry analyzer. This integrated HIL reporting system provides an effective screening tool for verifying specimen quality with regard to HIL and simplifies the laboratory workflow.
منابع مشابه
Evaluation of the revised serum calcium procedure used with the Du Pont automatic clinical analyzer.
We evaluated a revised serum calcium method (o-cresolphthalein complexone) used with the Du Pont aca. Our results correlated well with those obtained by atomic absorption spectrometry. Within-run and day-to-day coefficients of variation were 0.5 and 1.5%, respectively. Color produced and calcium concentration are linearly related and the relation is not affected by hemolysis, lipemia, or icterus.
متن کاملImproved method for measurement of inorganic phosphate in serum with a centrifugal analyzer.
A direct mehtod [Clin. Chim. Acta 46, 113 (1973)] for determination of inorganic phosphate in serum was adapted for use with a centrifugal analyzer. Contamination is minimized and analysis rate maximized by doing the reaction in the reagent wells of the transfer disc and by utilizing the high-speed spectrophotometric and data-reduction capabilities of the centrifugal analyzer. Hemolysis, icteru...
متن کاملAlbumin quantitation by dye binding and salt fractionation techniques.
Two dye-binding reagents, 2-(4’.hyd roxybenzeneazo)benzoic acid (HABA) and bromcresol green (BCG), for the quantitation of serum albumin have been compared with the biuret colorimetric procedure after salt fractionation. The linear regression equations for the biuret-BCG and the biuretHABA comparisons were y = 0.43 + O.9lx and y = -0.45 + l.l5x, respectively. Their corresponding correlation coe...
متن کاملGlucose in serum and cerebrospinal fluid by direct application of a glucose oxidase method.
Glucose is measured directly in 0.02 ml. of serum or cerebrospinal fluid by reaction with glucose oxidase. The hydrogen peroxide produced reacts with iodide in the presence of a catalyst to form molecular iodine. The iodine color is proportional to the glucose and is measured photometrically. The reaction is carried out directly on serum following preincubation with molecular iodine and can be ...
متن کاملFilling in the gaps with non-standard body fluids☆
OBJECTIVES Body fluid specimens other than serum, plasma or urine are generally not validated by manufacturers, but analysis of these non-standard fluids can be important for clinical diagnosis and management. Laboratories, therefore, rely on the published literature to better understand the validation and implementation of such tests. This study utilized a data-driven approach to determine the...
متن کامل