Forgotten Kirschner Wire Causing Severe Hematuria
نویسندگان
چکیده
Kirschner wire (K-wire) is commonly used in the treatment of hip fracture and its migration into pelvis leading to bladder injury is a very rare complication. Nonremoval of these devices either because of lack of followup or because of prolonged requirement due to disease process is associated with this complication. We report a case of a patient who presented with acute onset severe hematuria with clot retention secondary to perforation of bladder by a migrated K-wire placed earlier, for the treatment of hip fracture. Initial imaging showed its presence in the soft tissues of the pelvis away from the major vascular structures. Patient was taken for emergency laparotomy and wire was removed after cystotomy. Postoperative period was uneventful and patient was discharged in satisfactory condition. K-wires are commonly used in the management of fracture bones and their migration has been reported in the literature although such migration in the intrapelvic region involving bladder is very rare. Early diagnosis and prompt removal of such foreign bodies are required to avert potentially fatal involvement of major structures.
منابع مشابه
Intra-abdominal migration of a k-wire during revision total hip arthroplasty
Revision total hip arthroplasty in the setting of severe acetabular bone loss is a challenging problem that is becoming more common. Kirschner wires are often used during acetabular revision for temporary fixation of trial components. We describe an intraoperative migration of a Kirschner wire through the acetabulum into the peritoneal cavity, requiring acute laparoscopic removal.
متن کاملComparison of clinical results of surgical treatment for unstable distal clavicle fractures by transacromial pins with and without tension band wire.
BACKGROUND An unstable distal clavicle fracture (Neer type II) is an indication that surgical intervention is required. Numerous treatment options have been introduced, but there is no gold standard. METHODS We report on our experience of 29 consecutive cases, between 2002 and 2008, of acute unstable distal clavicle fracture (Neer type II) and operative treatment using transacromial pins with...
متن کاملOne century of Kirschner wires and Kirschner wire insertion techniques: a historical review.
A century ago, in 1909, Martin Kirschner (1879-1942) introduced a smooth pin, presently known as the Kirschner wire (K-wire). The K-wire was initially used for skeletal traction and is now currently used for many different goals. The development of the K-wire and its insertion devices were mainly influenced by the change in operative goals and by the introduction of antibiotics. The first versi...
متن کاملRemoval of Kirschner Wire That Migrated from the Pelvic Bone into the Right Ventricle of the Heart
A sixty-year-old man was admitted due to chest pain. He had a history of pelvic bone fracture fixation with Kirschner wire about 20 years earlier. On examination, we detected a Kirschner wire that had migrated into the right ventricle. Without cardiopulmonary bypass, we removed the migrating Kirschner wire via median sternotomy. The patient recovered without complications and was discharged on ...
متن کاملInfection rate of percutaneous Kirschner wire fixation for distal radius fractures.
PURPOSE To review the infection rate in 43 patients who underwent percutaneous Kirschner wire fixation for distal radius fractures. METHODS Records of 13 men and 30 women aged 25 to 86 (mean, 49) years who underwent closed reduction and percutaneous Kirschner wire fixation for unstable distal radius fractures were reviewed. Each fracture was fixed with 2 to 3 wires of 1.6-mm diameter. Kirschn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2014 شماره
صفحات -
تاریخ انتشار 2014