Development and multisite evaluation of an automated assay for B12 on the Abbott AxSYM analyzer.

نویسندگان

  • D H Wilson
  • J Yu
  • A Karian
  • J Kozlowski
  • S O'Reilly
چکیده

mutagenic primers are used in this method, it is important to note that they are equally mismatched to both the wild-type and mutant alleles. The specificity is introduced by extension of the primers, which introduces a different base at the first step. This is an important feature of the assay design, removing any possibility of allele-specific amplification, and produces a robust procedure. This technique provides an improved method of detection for both the C282Y and H63D mutations and diagnosis of hemochromatosis. By testing simultaneously for both mutations, this method decreases both the cost and time involved for each assay. The PCR is rapid and yields a consistently high-quality product. This assay is appropriate as a diagnostic test because results can be obtained quickly and confidently at a low cost, making it suitable for introduction into routine clinical laboratories. novel MHC class 1-like gene is mutated in patients with hereditary heamo-The hemochromatosis gene product complexes with the transferrin receptor and lowers its affinity for ligand binding. al. The significance of haemochromatosis gene mutations in the general population: implications for screening. Gut 1998;43:830 – 6. 13. Lynas C. A cheaper and more rapid polymerase chain reaction-restriction fragment length polymorphism method for the detection of the HLA-H gene mutations occurring in hereditary hemochromatosis [Letter]. Reliable measurement of serum B 12 is important in the differential diagnosis of megaloblastic anemia (1). Numerous assays, many of which are manual isotopic methods , have been developed for quantifying B 12. The shortcomings among the more recently developed automated methods include a need for frequent calibration, a lack of random access capability, complicated reagent preparations , and slow turnaround time. We have developed an automated, nonisotopic assay for measuring B 12 in human plasma and serum with the Abbott AxSYM random access analyzer (2) that improves on existing B 12 assays. During the assay, sample is first mixed with denaturant and extractant reagents. The denaturant reagent contains NaOH to unfold endogenous B 12-binding proteins to release B 12 for assay. These endogenous binding proteins include intrinsic factor (IF), transcobalamin-II (TC-II), and R-protein. IF exhibits almost no affinity for physiologically inactive forms of B 12 (including cobinamide), whereas TC-II and R-protein bind both physiologically inactive B 12 and physiologically active forms (e.g., cyano-cobalamin). The extractant reagents contain an excess of cobinamide and cyanide. The cobinamide occupies TC-II and R-protein binding sites to facilitate extraction of the B 12 …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Active B12: a rapid, automated assay for holotranscobalamin on the Abbott AxSYM analyzer.

BACKGROUND Conventional tests for vitamin B(12) deficiency measure total serum vitamin B12, whereas only that portion of vitamin B12 carried by transcobalamin (holotranscobalamin) is metabolically active. Measurement of holotranscobalamin (holoTC) may be more diagnostically accurate for detecting B(12) deficiency that requires therapy. We developed an automated assay for holoTC that can be used...

متن کامل

Performance characteristics of the ARCHITECT Active-B12 (Holotranscobalamin) assay.

BACKGROUND Vitamin B12 (cobalamin) is a necessary cofactor in methionine and succinyl-CoA metabolism. Studies estimate the deficiency prevalence as high as 30% in the elderly population. Ten to thirty percent of circulating cobalamin is bound to transcobalamin (holotranscobalamin, holoTC) which can readily enter cells and is therefore considered the bioactive form. The objective of our study wa...

متن کامل

Development and clinical evaluation of a recombinant-antigen-based cytomegalovirus immunoglobulin M automated immunoassay using the Abbott AxSYM analyzer.

A new microparticle enzyme immunoassay (MEIA), the Cytomegalovirus (CMV) Immunoglobulin M (IgM) test, was developed on the Abbott AxSYM analyzer. This test uses recombinant CMV antigens derived from portions of four structural and nonstructural proteins of CMV: pUL32 (pp150), pUL44 (pp52), pUL83 (pp65), and pUL80a (pp38). A total of 1, 608 specimens from random volunteer blood donors (n = 300),...

متن کامل

A barbiturate screening assay for the Abbott AxSYM analyzer.

A fluorescence polarization immunoassay for barbiturates on the Abbott AxSYM analyzer is described. The assay displayed dilution linearity up to 1200 ng/mL; coefficients of variation varied from 5.96 to 8.61%; recovery varied from 94.9 to 105.3%; and sensitivity was less than 40 ng/mL. Good correlation between the standard six- and factory two-point calibration methods was observed. The Immunoa...

متن کامل

Detection of immunoglobulin G antibodies to Toxoplasma gondii: Evaluation of two commercial immunoassay systems.

BACKGROUND Toxoplasmosis is a disease, which can cause severe congenital infection and is normally diagnosed by the detection of Toxoplasma gondii (T gondii)-specific antibodies in the serum of infected patients. Several different tests allow to distinguish recent from past infections and to quantify anti-T gondii-specific IgG, and the results can be used as markers for a chronic or recently se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 45 3  شماره 

صفحات  -

تاریخ انتشار 1999