Center-out echo-planar spectroscopic imaging with correction of gradient-echo phase and time shifts.
نویسندگان
چکیده
A procedure to prevent the formation of image and spectral Nyquist ghosts in echo-planar spectroscopic imaging is introduced. It is based on a novel Cartesian center-out echo-planar spectroscopic imaging trajectory, referred to as EPSICO, and combined with a correction of the gradient-echo phase and time shifts. Processing of homogenous sets of forward and reflected echoes is no longer necessary, resulting in an optimized spectral width. The proposed center-out trajectory passively prevents the formation of Nyquist ghosts by privileging the acquisition of the center k-space line with forward echoes at the beginning of an echo-planar spectroscopic imaging dwell time and by ensuring that all k-space lines and their respective complex conjugates are acquired at equal time intervals. With the proposed procedure, concentrations of N-acetyl aspartate, creatine, choline, glutamate, and myo-inositol were reliably determined in human white matter at 3 T.
منابع مشابه
Prospective Correction of Spatially Non-Linear Phase Patterns for Diffusion-Weighted FSE Imaging Using Tailored RF Excitation Pulses
Introduction: Echo planar imaging (EPI) is the workhorse for in vivo diffusion-weighted (DW) imaging; however it suffers from spatial distortions and signal loss particularly at tissue-air or bone interfaces. Single shot fast spin echo (ssFSE) does not suffer these limitations, but requires precise control of the signal phase at the start of the refocusing pulse train to avoid signal losses (CP...
متن کاملEffect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI
Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...
متن کاملCorrection for EPI distortions using multi-echo gradient-echo imaging.
A novel and effective technique is described for distortion correction in echo planar imaging (EPI) utilizing the field maps derived from multi-echo gradient-echo images. The distortions from different off-resonance related factors such as field inhomogeneity, eddy current effect, radiofrequency pulse frequency offset, and chemical shift effect can be simultaneously reduced to a great extent. W...
متن کاملZero and first-order phase shift correction for field map estimation with dual-echo GRE using bipolar gradients.
A simple phase error correction technique used for field map estimation with a generally available dual-echo gradient-echo (GRE) sequence is presented. Magnetic field inhomogeneity maps estimated using two separate GRE volume acquisitions at different echo times are prone to dynamic motion errors between acquisitions. By using the dual-echo sequence, the data are collected during two back-to-ba...
متن کاملSimultaneous Acquisition of Metabolite and Water Signals in 3D Echo Planar Spectroscopic Imaging
Introduction Echo planar spectroscopic imaging (EPSI) is one of several approaches to speeding up acquisitions of metabolite spectra from multiple voxels [1, 2]. However, EPSI measurements are very sensitive to temporally and spatially dependent phase and frequency shifts that arise from eddy current caused by oscillating readout gradient of the EPSI sequence. As a result, these phase and frequ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 70 1 شماره
صفحات -
تاریخ انتشار 2013