Catheterless Long-Term Ambulatory Urodynamic Measurement Using a Novel Three-Device System
نویسندگان
چکیده
AIMS Long-term urodynamics are required because bladder-emptying disorders are often not clearly revealed by conventional urodynamics. Patients with severe clinical overactive bladder symptoms, for instance, often show normal results. This may be due to the short evaluation time and psychological factors that complicate conventional urodynamics. This study aimed to develop an ambulatory three-component urodynamic measurement system that is easy to operate, registers urodynamic parameters for several days, and has no negative impact on the patient. METHODS We developed an intravesical capsule combined with a hand-held device to register voiding desire and micturition, and an alarm pad device that detects urine loss. Recently, the intravesical capsule and its proven function were detailed in the literature. Here, we present detailed in vitro results using a female bladder model. The flexible capsule was C-shaped to minimize the risk of expulsion from the bladder during micturition. Results of biocompatibility evaluation of the intravesical capsule, which is called Wille Capsule (WiCa) are described. RESULTS The WiCa with an oval nose and a maximum outer diameter of 5.5 mm was easily inserted through a 25-French cystoscope. Removing the WiCa by grasping the nose using the female model with bladder was easily conducted. Expulsion of the WiCa during voiding was avoided through a novel C-shaped device design. Based on in vitro cytotoxicity studies, the capsule is a promising and safe device. CONCLUSION Our novel system is an innovative minimally-invasive tool for accurate long-term urodynamic measurement, and does not require inserting a transurethral catheter.
منابع مشابه
Very Tiny Inner Bladder Pressure Sensing System for Long Term Ambulatory Urodynamic Monitoring
2 This paper introduces a tiny inner bladder pressure sensing system for long term ambulatory urodynamic monitoring. In order to realize this system, a small System-on-a Chip (SoC) called Medical Domain Specific SOC, Type-I (MeSOC-I) has been developed. MeSOC-I enables an inner bladder pressure sensing system to conduct more than 72 hours measurement with a small battery.
متن کاملAccuracy of a Custom Physical Activity and Knee Angle Measurement Sensor System for Patients with Neuromuscular Disorders and Gait Abnormalities
Long-term assessment of ambulatory behavior and joint motion are valuable tools for the evaluation of therapy effectiveness in patients with neuromuscular disorders and gait abnormalities. Even though there are several tools available to quantify ambulatory behavior in a home environment, reliable measurement of joint motion is still limited to laboratory tests. The aim of this study was to dev...
متن کاملComparative analysis of profit between three dissimilar repairable redundant systems using supporting external device for operation
The importance in promoting, sustaining industries, manufacturing systems and economy through reliability measurement has become an area of interest. The profit of a system may be enhanced using highly reliable structural design of the system or subsystem of higher reliability. On improving the reliability and availability of a system, the production and associated profit will also increase. Re...
متن کاملLong Term Follow-Up in Feminine Stress Urinary Incontinence Ambulatory Surgery by Using a Single Incision Transobturator Mesh
Objective: To evaluate short and long-term results obtained from ambulatory surgical treatment of feminine stress urinary incontinence (SUI), by using a transobturator mesh (TOT) and a single Contasure-Needleless incision (Neomedic-International). Patients and Method: Between January 2007 and December 2015, 215 patients suffering from SUI received surgery under local anaesthesia and strict ambu...
متن کاملDifferentiation of lower urinary tract dysfunctions: The role of ambulatory urodynamic monitoring.
OBJECTIVES To determine the value of ambulatory urodynamic monitoring in the assessment of patients with lower urinary tract symptoms. METHODS This was a cross-sectional study including patients who underwent both conventional urodynamic and ambulatory urodynamic assessment at our Center between December 2002 and February 2013. The ambulatory urodynamic studies were interpreted in a standardi...
متن کامل