Determination of ultra-trace levels of priority PBDEs in water samples by isotope dilution GC(ECNI)MS using 81Br-labelled standards.

نویسندگان

  • Adriana González-Gago
  • Sicco H Brandsma
  • Pim E G Leonards
  • Jacob de Boer
  • Juan Manuel Marchante-Gayón
  • J Ignacio Garcia Alonso
چکیده

A gas chromatography electron capture negative ionization mass spectrometry (GC(ECNI)MS) procedure for the determination of priority polybrominated diphenyl ethers (PBDEs; congeners 28, 47, 99, 100, 153 and 154) in water samples at regulatory EU levels has been developed. The method is based on the use of (81)Br-labelled PBDEs for isotope dilution analysis and the measurement of (79)Br/(81)Br isotope ratios in gas chromatography peaks with the electron capture negative ionization technique. The suitability of this ion source for the precise and accurate measurement of bromine isotope ratios has been demonstrated. The general ECNI-IDMS procedure was evaluated by the analysis of NIST SRM 1947 (Lake Michigan fish tissue) with satisfactory results. For the analysis of water samples, 500 mL of the samples were spiked with the labelled PBDEs and extracted with 10 mL isooctane for 30 min. The extract was evaporated down to ca. 100 μL and injected in the GC(ECNI)MS. Detection limits ranged from 0.014 (-1) to 0.089 pg mL(-1) depending on the congener. Recoveries from real water samples, spiked at a level of 0.5 pg mL(-1), ranged from 77% to 102%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of the retention behaviour of monofluorinated analogues of Polybrominated Diphenylethers (F-PBDEs) in gas chromatography

Introduction Polybrominated diphenyl ethers (PBDEs) are globally distributed in the environment. They have been used as flame retardants for over 2 decades [1]. PBDEs have been found to bioaccumulate and there is also a concern about the health effects of PBDE exposure due to their potential endocrine disrupting properties. PBDEs are structurally similar to polychlorinated biphenyls (PCBs) and ...

متن کامل

Simultaneous analysis of phthalates, adipate and polycyclic aromatic hydrocarbons in edible oils using isotope dilution-gas chromatography-mass spectrometry.

A method for simultaneous determination of 12 priority phthalates, adipate and polycyclic aromatic hydrocarbons (PAHs) in edible oils by isotope dilution-gas chromatography-mass spectrometry (ID-GC-MS) was developed for fast, accurate and trace analysis. The extraction and clean-up procedures were optimised, and using stable isotope-labelled internal standards for each analyte, relative standar...

متن کامل

Trace-level determination of 1,4-dioxane in water by isotopic dilution GC and GC-MS.

The volatile and polar solvent 1,4-dioxane has recently been reported as a contaminant of ground and surface waters, establishing the need to determine this substance in drinking water. This investigation established that 1,4-dioxane can be determined in water by various techniques including direct aqueous injection (DAI) gas chromatography (GC) and purge and trap GC-mass spectrometry (MS). Pur...

متن کامل

Validation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS

Dispersive liquid liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (...

متن کامل

Determination of Butyltin Compounds in Environmental Samples by Isotope Dilution GC-MS Application

A GC-MS with electron impact ionization was used for the development of a speciation method for the simultaneous determination of monobutyl-, dibutyl-, and tributyltin in environmental samples (waters, sediments, and biota). The method is based on the use of a mixed spike containing Sn-enriched monobutyltin (MBT), dibutyltin (DBT), and tributyltin (TBT) for isotope dilution analysis. The mixed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 401 8  شماره 

صفحات  -

تاریخ انتشار 2011