Three-year analysis of treatment efficacy, cosmesis, and toxicity by the American Society of Breast Surgeons MammoSite Breast Brachytherapy Registry Trial in patients treated with accelerated partial breast irradiation (APBI).
نویسندگان
چکیده
BACKGROUND This report presents 3 years of data on treatment efficacy, cosmetic results, and toxicities for patients enrolled on the American Society of Breast Surgeons MammoSite (Cytyc, Bedford, Mass) Breast Brachytherapy Registry Trial. METHODS A total of 1440 patients (1449 cases) with early stage breast cancer who were undergoing breast-conserving therapy were treated with the MammoSite device to deliver accelerated partial breast irradiation (APBI) (34 Gy in 3.4 Gy fractions). Of these, 1255 (87%) cases had invasive breast cancer (IBC; median size = 10 mm), and 194 (13%) cases had ductal carcinoma in situ (DCIS; median size = 8 mm). Median follow-up was 30.1 months. RESULTS Twenty-three (1.6%) cases developed an ipsilateral breast tumor recurrence (IBTR) for a 2-year actuarial rate of 1.04% (1.11% for IBC and 0.59% for DCIS). No variables were associated with IBTR. Six (0.4%) patients developed an axillary failure. The percentages of breasts with good to excellent cosmetic results at 12 (n = 980), 24 (n = 752), 36 (n = 403), and 48 months (n = 67 cases) were 95%, 94%, 93%, and 93%, respectively. Breast seromas were reported in 23.9% of cases (30% in open-cavity implants and 19% in closed-cavity implants). Symptomatic seromas occurred in 10.6% of cases, and 1.5% of cases developed fat necrosis. A subset analysis of the first 400 consecutive cases enrolled was performed (352 with IBC, 48 DCIS). With a median follow-up of 37.5 months, the 3-year actuarial rate of IBTR was 1.79%. CONCLUSIONS Treatment efficacy, cosmesis, and toxicity 3 years after treatment with APBI using the MammoSite device are good and similar to those reported with other forms of APBI with similar follow-up.
منابع مشابه
Analysis of treatment efficacy, cosmesis, and toxicity using the MammoSite breast brachytherapy catheter to deliver accelerated partial-breast irradiation: the william beaumont hospital experience.
PURPOSE To review our institution's experience of treating patients with the MammoSite (Cytyc Corp., Marlborough, MA) breast brachytherapy catheter to deliver accelerated partial-breast irradiation (APBI), for determining short-term treatment efficacy, cosmesis, and toxicity. METHODS AND MATERIALS From January 2000 to April 2006, 80 patients treated with breast-conserving therapy (BCT) receiv...
متن کاملWBRT vs. APBI: an interim report of patient satisfaction and outcomes
PURPOSE To determine differences in patient's reported quality of life and self-reported breast cosmesis between whole breast radiation therapy (WBRT) and accelerated partial breast irradiation (APBI) via single and multi-lumen high-dose-rate (HDR) brachytherapy for women with early stage breast cancer. MATERIAL AND METHODS Patient information was retrospectively reviewed and survey data were...
متن کاملBreast conserving surgery and accelerated partial breast irradiation using the MammoSite system: initial clinical experience.
HYPOTHESIS Balloon catheter-based accelerated partial breast irradiation (APBI) may result in desirable short-term outcomes in patients undergoing breast conserving surgery. DESIGN Prospective consecutive case series. SETTING Tertiary multidisciplinary referral center. PATIENTS Forty selected patients with invasive breast carcinoma undergoing breast conserving surgery and MammoSite device...
متن کاملA Comparison of Skin Dose Delivered with MammoSite and Multicatheter Breast Brachytherapy
Background: Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and Lung doses are correlated with toxicity in patients treated with breast brachytherapy.Objective: To investigate the percentage of the dose received by critical organ (skin), thermoluminescence detec...
متن کاملAcute toxicity and early cosmetic outcome in patients treated with multilumen balloon brachytherapy with skin spacing ≤ 7.0 millimeters
PURPOSE To review institutional experience treating patients who underwent breast conserving surgery and adjuvant accelerated partial breast irradiation with multilumen balloon brachytherapy (MLB) with close skin spacing (≤7 mm). MATERIAL AND METHODS Since July 2009, 26 patients with skin spacing ≤ 7.0 mm were treated with breast-conserving therapy and adjuvant MLB brachytherapy. Patients wer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cancer
دوره 112 4 شماره
صفحات -
تاریخ انتشار 2008