Urine color testing and isoniazid monitoring.
نویسندگان
چکیده
2003;124;2405 Chest Graham F. Cope and Ruth Whitfield Urine Color Testing and Isoniazid Monitoring /chest/124/6/2405.full.html and services can be found online on the World Wide Web at: The online version of this article, along with updated information ) ISSN:0012-3692 http://www.chestjournal.org/misc/reprints.shtml ( of the copyright holder. may be reproduced or distributed without the prior written permission Northbrook IL 60062. All rights reserved. No part of this article or PDF by the American College of Chest Physicians, 3300 Dundee Road, 2007 Physicians. It has been published monthly since 1935. Copyright CHEST is the official journal of the American College of Chest
منابع مشابه
Testing for isoniazid. An evaluation of the Arkansas method.
To better treat and eliminate tuberculosis, patient compliance must be improved. Compliance can be evaluated by measuring a drug or its metabolite in the urine. In Arkansas, a simple colorimetric method of checking the urine for isoniazid (the Potts-Cozart test) has been used for many years, but it is relatively unknown outside that state and its reliability has not been confirmed. To evaluate ...
متن کاملA sensitive urine-test method for monitoring the ingestion of isoniazid.
A method is described for monitoring the ingestion of isoniazid based on detecting its metabolites, isonicotinic acid, and isonicotinylglycine in the urine. The sensitivity of the method is high so that reliably positive results were obtained up to about 24 hours after the ingestion of 100 mg isoniazid. The method should facilitate monitoring the taking of isoniazid by tuberculosis patients and...
متن کاملSimple and Rapid Method for Simultaneous Determination of Isoniazid and Acetyl Isoniazid in Urine by HPLC
A high performance liquid chromatographic method for simultaneous determination of isoniazid and acetyl isoniazid in urine was developed. Urine samples were filtered through Whatman number 1 filter paper and diluted filtrate was directly injected into C8 column (250mm). The mobile phase comprised of water and methanol in the ratio of 85:15. The analytes were detected at a wavelength of 274nm. T...
متن کاملisoniazid . monitoring the ingestion of A sensitive urine - test for
SMA 12/60 method. Its improved standardisation is of considerable clinical importance. Its economy (cost per test is less than half of that with SMA 12/60) and other advantages merit consideration for its general application to the determination of uric acid in serum and other biological fluids. Furthermore, the principles outlined here can also be adapted to any continuous-flow automated system.
متن کاملElectronic monitoring of treatment adherence and validation of alternative adherence measures in tuberculosis patients: a pilot study.
OBJECTIVE To assess adherence to community-based directly observed treatment (DOT) among Tanzanian tuberculosis patients using the Medication Event Monitoring System (MEMS) and to validate alternative adherence measures for resource-limited settings using MEMS as a gold standard. METHODS This was a longitudinal pilot study of 50 patients recruited consecutively from one rural hospital, one ur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 124 6 شماره
صفحات -
تاریخ انتشار 2003