A simple optical apparatus for measuring the corneal thickness, and the average thickness of the human cornea.

نویسندگان

  • D M MAURICE
  • A A GIARDINI
چکیده

PREVIOUS methods of measuring the corneal thickness in the living eye have recently been extensively reviewed and criticized by von Bahr (1948a), who devised an ingenious method (1948a, b) of overcoming the practical difficulties and theoretical objections of its forerunners. He employed an apparatus consisting of two rotating glass plates, coupled by gearing, which were mounted in front of the condensing lens and microscope of a slit lamp, so that the aperture of each was half covered by one of these plates. On rotation, the reflection of the slit in the corneal endothelium may be displaced in the field of view of the microscope and brought into coincidence with that in the epithelium. By noting the angle of rotation, the thickness of the cornea may be obtained from a curve derived by calculation. Von Bahr claimed for this instrument that it was simple and easy to handle and gave a satisfactory degree of accuracy and consistency. We were projecting a series of experiments in which changes in the thickness of the cornea in rabbits were to be followed after its metabolism was interfered with in various ways. Accordingly, a similar apparatus was constructed and attached to a Haag-Streit slit lamp. Experience showed, however, that there were disadvantages in this arrangement which made it difficult to use with a normal eye, and quite impossible with disturbed corneae for which it had been intended. There are eight images of the slit formed by this optical system when operating correctly, and in our model an extra " ghost " image due to a double reflection within the glass plates. Two of these images, one an epithelial, and one an endothelial reflex, have to be aligned, but this is not easy as the former is some thirty times the brighter, and its dazzle conceals the other when they are adjoining. Again, the closeness of the glass plates to the slit-lamp and microscope lenses resulted in the light which traversed the first

منابع مشابه

Cigarette Smoking and Pachymetry and Specular Microscopy Parameters of Cornea; A Systematic Review and Meta-analysis

Purpose: To investigate the effect of smoking on corneal parameters, including Endothelial Cell Density, Central Corneal Thickness, Percent of Hexogonality, and Coefficient of Variation. Methods: This study was a systematic review and meta-analysis of published articles until the end of February 2019. To do this, the first search was done for creditable medical databases such as PubMed, and ISI...

متن کامل

بررسی نتایج تکنیک جدید پیوند لایه ای قرنیه با استفاده از میکروکراتوم

          This study was performed to evaluate the efficacy of anterior keratoplasty    with microkeratome in the improvement of visual acuity (V.A) in superficial    corneal disorders in patients admitted to Labbfi Nezhad hospital and Tehran    Bassir Clinic .         &nbs...

متن کامل

In vitro measurement of rabbit corneal epithelial thickness using ultrahigh resolution optical coherence tomography.

The objective of this study was to reproducibly measure corneal epithelial thickness centrally and at the limbus in the rabbit cornea using ultrahigh resolution optical coherence tomography (OCT). Twelve freshly enucleated New Zealand white rabbit eyes were kept in a moist chamber at 4 degrees C. An ultrahigh resolution OCT system with a spatial resolution of 1.3 microm was used to image the co...

متن کامل

Monitoring of rabbit cornea response to dehydration stress by optical coherence tomography.

PURPOSE To evaluate the application of optical coherence tomography (OCT) for continuous noninvasive monitoring and quantification of the dynamics of corneal response after exposure of the cornea to dehydrating stress. METHODS The changes in central corneal thickness (CCT) and scattering properties of the cornea were monitored with OCT in rabbit cornea in vivo after topical application of a g...

متن کامل

Comparison of artemis 2 ultrasound and Visante optical coherence tomography corneal thickness profiles.

PURPOSE To compare corneal thickness profiles of cross-sections of cornea determined by arc-scanned immersion ultrasound and optical coherence tomography (OCT). METHODS Corneas of 28 eyes from 14 participants were scanned in triplicate using the Artemis 2 high-frequency arc-scanned ultrasound system (ArcScan Inc) and the Visante OCT system (Carl Zeiss Meditec). Corneal thickness and reproduci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • The British journal of ophthalmology

دوره 35 3  شماره 

صفحات  -

تاریخ انتشار 1951