Residual dentin thickness in mesial roots of mandibular molars prepared with Lightspeed rotary instruments and Gates-Glidden reamers.

نویسندگان

  • Offer Zuckerman
  • Alexander Katz
  • Raphael Pilo
  • Aviad Tamse
  • Zvi Fuss
چکیده

OBJECTIVE We sought to measure the residual dentin thickness (RDT) in the mesial roots of mandibular molars after instrumentation with Lightspeed and Gates-Glidden rotary instruments. Study design Thirty extracted, untreated human mesial roots of mandibular molars were separated from the distal roots and embedded in clear polyester resin. The roots were cut horizontally at 1, 4, and 7 mm short of the anatomic apex. The diameter of each mesiobuccal canal was measured by using a stereo measuring microscope at each level in the buccolingual and mesiodistal directions. The dentin thickness was measured in each level in the mesial, distal, buccal, and lingual directions. Sections were reassembled with a muffle. The canals were enlarged to the working length with Lightspeed rotary instruments, of which the average size used was a No. 50 file. The coronal third was flared with No. 2 Gates-Glidden reamers. Slices were separated again, and the RDT and canal diameters were measured. RESULTS The minimal measured RDT after instrumentation at the 1-, 4-, and 7-mm levels was 0.70 +/- 0.28 mm, 1.04 +/- 0.18 mm, and 1.09 +/- 0.19 mm, respectively. The average diameter of the canals after instrumentation at the 1-, 4-, and 7-mm levels was 0.50 +/- 0.04 mm, 0.52 +/- 0.05 mm, and 0.74 +/- 0.08 mm, respectively. The canal diameter did not exceed one third of the root diameter at all levels. CONCLUSIONS Root canal preparation of mandibular mesial roots with Lightspeed instruments to No. 50 in the apical third and Gates-Glidden reamers to No. 2 in the coronal third does not significantly decrease the RDT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Effect of ProTaper and Gates-Glidden Drills On the Remaining Root Dentin Thickness at the Coronal Region of the Root

Background and Aim: The purpose of this study was to evaluate residual dentin thickness of the root and the area of the canal lumen in the coronal region of the mesiobuccal and mesiolingual canals of the lower first molars after canal preparation with the common method of using hand files and Gates Glidden drills or ProTaper rotary files, by Spiral Ct-Scan. Materials and Methods: In this exp...

متن کامل

Comparison of the effects of TripleGates and Gates-Glidden burs on cervical dentin thickness and root canal area by using cone beam computed tomography

UNLABELLED The search for new instruments to promote an appropriate cervical preparation has led to the development of new rotary instruments such as TripleGates. However, to the best of the authors' knowledge, there is no study evaluating TripleGates effect on the "risk zone" of mandibular molars. OBJECTIVES The aim of this study was to evaluate the effects of a crown-down sequence of Gates-...

متن کامل

Effects of Gates-Glidden, LA Axxess and orifice shaper burs on the cervical dentin thickness and root canal area of mandibular molars.

This study evaluated the increase of the instrumented area and dentin thickness in the mesial and distal aspects of mesial canals of mandibular molars after the use of Gates Glidden (GG), LA Axxess (LA) and Orifice Shaper (OS) instruments. A total of 53 canals from 27 mandibular molars were embedded in resin and divided into 3 groups. The roots were sectioned 3 mm below the cementoenamel juncti...

متن کامل

The minimum residual root thickness after using ProTaper, RaCe and Gates-Glidden drills: A cone beam computerized tomography study

OBJECTIVE The aim of this study was to evaluate the minimum residual root thickness (MRRT) of the danger zone after preflaring of the mesio-buccal (MB) canal of mandibular first molars using ProTaper, RaCe and Gates-Glidden (GG) drills as coronal shapers by cone beam computerized tomography (CBCT). MATERIALS AND METHODS In this experimental study, the initial CBCT scans of 75 MB canals of man...

متن کامل

A reconstructed computerized tomographic comparison of Ni-Ti rotary GT files versus traditional instruments in canals shaped by novice operators.

AIM The aim of this study was to compare the effects of preparation with conventional stainless steel Flexofiles and Gates Glidden burs versus nickel-titanium GT rotary files in the shaping of mesial root canals of extracted mandibular molars. METHODOLOGY A total of 54 canals from 27 mesial roots of mandibular molar teeth were prepared using one of two methods by novice dental students. One c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics

دوره 96 3  شماره 

صفحات  -

تاریخ انتشار 2003