Examiner's finger-mounted fetal tissue oximetry: a preliminary report on 30 cases.
نویسندگان
چکیده
OBJECTIVE To describe preliminary experience with a finger-mounted fetal tissue oximetry probe during the 2nd stage of labor. MATERIALS AND METHODS A total of 30 term pregnant women without pregnancy complications were recruited. We measured fetal tissue oxygen saturation (FtO2) by using a finger-mounted fetal tissue oximetry during cervical examinations in the 2nd stage of labor. The data capturing rate of FtO2 and the interclass correlation coefficient were also examined. The mean FtO2 was compared to the neonatal condition assessed by the levels of umbilical cord blood. RESULTS FtO2 was obtained in all cases, regardless of wetness, hair color, the part of the fetal head that was exposed, rotation of the fetus, color of amniotic fluid, and caput succedaneum. The mean FtO2 was 65.5%±8.58% in normal neonates [Apgar score >7 (1 min), n=25]. The mean FtO2 was significantly correlated with umbilical cord arterial pH (r=0.52, P=0.0030, n=30), but not with umbilical cord arterial partial pressure of oxygen. The interclass correlation coefficient was 0.94. CONCLUSIONS Tissue oxygen saturation of the fetal head was obtained easily by the examiner's finger-mounted fetal tissue oximetry.
منابع مشابه
Craniofacial tissue oxygen saturation is associated with blood pH using an examiner's finger-mounted tissue oximetry in mice.
Although fetal scalp blood sampling is an examination to assess fetal acidosis during the intrapartum period, it has not been widely used by obstetricians because of its invasiveness. We have developed a small, portable oximetry with a sensor attached to the examiner's finger. Our previous report using this oximetry concluded that fetal head tissue oxygen saturation (StO 2 StO2 ) correlated wit...
متن کاملExaminer's finger-mounted fetal tissue oximetry.
The best way to assess fetal condition is to observe the oxygen status of the fetus (as well as to assess the condition of infants, children, and adults). Previously, several fetal oximeters have been developed; however, no instrument has been utilized in clinical practice because of the low-capturing rate of the fetal oxygen saturation. To overcome the problem, we developed a doctor's finger-m...
متن کاملPredictive value of pulse oximetry for the development of fetal acidosis.
AIMS To determine the predictive value of fetal pulse oximetry (FPO) for the development of fetal acidosis in cases of non-reassuring fetal heart rate (FHR). METHODS In a prospective observational study, pulse oximetry monitoring was examined in cases of non-reassuring FHR during singleton cephalic delivery at 36-42 weeks' gestation. The study examined whether fetal arterial oxygen saturation...
متن کاملTrans-abdominal monitoring of fetal arterial blood oxygenation using pulse oximetry.
Pulse oximetry (oxygen saturation monitoring) has markedly improved medical care in many fields, including anesthesiology, intensive care, and newborn intensive care. In obstetrics, fetal heart rate monitoring remains the standard for intrapartum assessment of fetal well being. Fetal oxygen saturation monitoring is a new technique currently under development. It is potentially superior to elect...
متن کاملBuccal inlay skin onlay: Preliminary report of a one stage technique in cripple hypospadias surgery
Hypospadias failure is a challenging problem requiring much of expertise and perseverance for repair. Most of the time a healthy tissue must be grafted in place of scarred tissue. These techniques are usually accomplished in multiple surgical sessions since primary graft tubularization has been linked with increased complications Patients and method: Eleven patients with mid shaft to distal hy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of perinatal medicine
دوره 44 7 شماره
صفحات -
تاریخ انتشار 2016