Late migration of a Sideris buttoned device for occlusion of atrial septal defect.

نویسندگان

  • Timothy Cotts
  • Peter J Strouse
  • Joseph N Graziano
چکیده

We describe a 17-year-old patient with an atrial septal defect who underwent device closure with a second generation Sideris buttoned device at 4 years of age. She presented 13 years after the procedure with the acute onset of chest discomfort, at which time a chest radiograph showed migration of the wire of the right atrial counter-occluder to the lateral aspect of the right atrial wall, with an associated right atrial perforation. The patient underwent uneventful surgical device retrieval and atrial septal defect closure. Late migration of a portion of the Sideris buttoned device can occur, suggesting the need for continued follow up, and a high index of suspicion for device failure should a patient become symptomatic.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transvenous atrial septal defect occlusion in piglets with a "buttoned" double-disk device.

The feasibility and safety of transvenous closure of atrial septal defects by a new device was tested in 20 piglets, in which atrial septal defects were created by foramen ovale dilatation with angioplasty balloons. The device was small enough to be introduced in a 7F or 8F sheath, and it measured 20-25 mm. It has no hooks and consists of a foam occluder from the left atrium and a counter-occlu...

متن کامل

International experience with secundum atrial septal defect occlusion by the buttoned device.

Several devices are available for transcatheter occlusion of atrial septal defect. This report describes the international experience with the buttoned device. During a 4.5-year period ending in February 1993, 180 transcatheter atrial septal defect occlusions were performed with the buttoned device. Patient age varied between 0.6 and 76 years and stretched atrial defect diameter between 5 and 2...

متن کامل

Doppler forward flow profiles of St. Jude Medical prosthetic valves in pediatric patients.

tion versus transcatheter closure of ASD before comparisons can he made. The length of stay for patients undergoing transcatheter closure is reported to he 2 to 3 days.1-5y9 In our study, the most recent average length of stay was 6.1 days, hut since this study has ended, the length of stay for ASD operation is ~4 days. Recent reports on transcatheter closure devices do not discuss costs, inclu...

متن کامل

Transcatheter closure of residual atrial septal defect following implantation of buttoned device.

We report a case in which residual shunting after a buttoned device occlusion of atrial septal defect (ASD) was eliminated by transcatheter retrieval of a portion of the device, followed by implantation of a second device. This method may be helpful for those patients with residual ASDs who decline surgical device retrieval and defect closure.

متن کامل

Integrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty

Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions

دوره 68 5  شماره 

صفحات  -

تاریخ انتشار 2006