Polyglycolide bioabsorbable screws in the treatment of ankle fractures.

نویسندگان

  • W D Hovis
  • R W Bucholz
چکیده

Twenty-one patients with unstable medial malleolar, bimalleolar, or trimalleolar ankle fractures underwent open reduction and internal fixation of the medial malleolus with 4.5-mm polyglycolide screws. All lateral malleolar fractures were internally fixed with standard metallic implants. Radiographic and clinical follow-up results were available on 16 of 21 patients. All fractures healed at an average of 3.4 months (range, 3-6 months), and there were no medial wound infections. Eight of 16 patients developed an inflammatory reaction to the biodegradable polyester at 3 to 4 months after implantation, including one who developed a sterile draining sinus tract. No surgical or nonsurgical treatment was required in those eight patients. We conclude that whereas polyester screws yield union rates and functional results similar to those of metallic screws in the treatment of medical malleolar fractures, the use of polyglycolide screws is associated with an unacceptable rate of inflammatory reactions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Bioabsorbable Implants for the Fixation of Metaphyseal Bone An Experimental and Clinical Study

The purpose of the present study was to investigate the suitability of bioabsorbable drawn selfreinforced polyglycolide (SR-PGA) and poly-L/DL-lactide 70:30 (SR-PLA70) implants in experimental and clinical fixations of cancellous bone osteotomies, arthrodeses and fractures. The study consists of a set of two experimental and two clinical studies, including 109 experimental animals and 87 patien...

متن کامل

Treatment of syndesmotic disruptions of the ankle with bioabsorbable screw fixation.

BACKGROUND Bioabsorbable implants have restricted indications because of their unique biochemical properties and their inferior biomechanical properties compared with those of conventional metallic implants. The purpose of this prospective study was to assess the efficacy of screws made of polylevolactic acid (PLLA) in the treatment of syndesmotic disruptions associated with ankle fractures and...

متن کامل

Bioabsorbable miniplating versus metallic fixation for metacarpal fractures.

Bioabsorbable implants offer an attractive alternative to metallic implants to stabilize small bone fractures in the hand. Self-reinforced bioabsorbable miniplating for metacarpal fractures was studied in bones from cadavers and compared with standard metallic fixation methods. One hundred twelve fresh-frozen metacarpals from humans had three-point bending and torsional loading after transverse...

متن کامل

Transphyseal bioabsorbable screws cause temporary growth retardation in rabbit femur.

A self-reinforced bioabsorbable poly-L-lactide/polyglycolide (SR-PLGA) 80/20 screw 2.0 mm in diameter was implanted transphyseally across the distal growth plate of the right femur in 24 immature rabbits. Radiologic evaluation revealed a mean shortening of 3.1 mm at 3 weeks, 11.1 mm at 6 weeks, 9.3 mm at 24 weeks, 9.0 mm at 48 weeks, and 12.6 mm at 72 weeks compared with the intact contralatera...

متن کامل

NOVEL BIOABSORBABLE ACL RECONSTRUCTION SCREWS

This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Foot & ankle international

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 1997